2
Product description
2.1
General description
•
Automatic identification of connected battery.
•
Automatic identification of a charged battery guarantees optimum charging results.
•
Automatic identification of a defective battery.
•
The recharging phase guarantees maximum run time of the battery.
•
Charge status display
•
Overcharge protection
•
Wide-range input make worldwide use possible.
•
Voltage monitor prevents deep discharging and battery short-circuits.
2.2
LED display
Fig. 2-1
LED
Operating status
Off
Lights up green
Off
Flashing green at
0.5 Hz
Flashing green at 1 Hz Battery charging, charge state > 80%
Lights up green
Lights up red
Flashing red at 2 Hz
2069b_1_5_en_bedingt.fm, 04.08.2015
EN
Result
No mains supply
Power supply connected
No battery contact
Battery charging, charge state < 80%
Battery is charged
Temperature in battery too high
Battery fault:
•
Short circuit
•
Faulty cell
•
Faulty electronics
P2069BA/INT 2015-06
Product description
Symbol
19