EN
> POSITIONING OF THE CHIMNEY FOR INDOOR
APPLICATION
(see fig. M)
WARNING: In case of operation indoors,
adequate ventilation and gas venting must be
assured.
Sometimes a chimney is necessary to remove the
exhaustsfrom the pressure cleaner.
This problem hasn't to be faced when the machine
operates outdoor, but when it's installed indoor,
the following recommendations must be follo-
wed:
- The chimney path must be always in ascent,
straight vertical if possible, and preferably not
exceeding a 5 m lenght.
- The exit of the chimney must be sheltered to avoid
the dripping of rain and to allow the exaust flow.
- The chimney section A must be 3 times the outlet
chimney of the machine B and at distance of at
least 20 cm.
It must be underlined that the above recommen-
dations are extremely important to prevent the
condensate from back dripping into the machine.
The exausts contain sulphuric acid, condensating
at a temperature of approximately 180° C. The
condensation shall be avoid, but in any case the
condensate from chimney shall not enter the ma-
chine.
The non observance of these recommendations
may lead to the damage of the machine.
CHIMNEY SECTION: 3 times the area of chimney
Chimney pipe diameter = 150 mm.
CHIMNEY SECTION FOR 2 BOILER: 6 times the area
of chimney.
Chimney pipe diameter = 225 mm.
> INSTALLATION AND START-UP
IMPORTANT: The machine installation en-
vironment should be kept at between 10°C and
35°C.
vedi fig. C
- Connect Steam hose ⑲ to gun and to steam
outlet ⑭,
- turn up the safety catch fig. D.
- then open the steam tap ⑮
WARNING: Danger from hot steam.
> FUELLING
DIESEL
(see fig. A) 18 l
Fill the tank with the fuel indicated on the technical
data plate (Diesel)
In order not to damage the fuel pump, ensure that
the tank never empties while running.
WARNING: Use of unsuitable fuel may result in
dangerous situations.
WATER
(see fig. A)
see section on "WATER SUPPLY"
> TEMPERATURE ADJUSTMENT
(see fig. B)
Adjust the temperature by means of the thermo re-
gulator ⑪ situated on the control panel.
This machine is equipped with an electronic thermo
regulator to check and adjust the boiler temperatu-
re as well as the pressure from min. 5 bar to max.
10 bar.
- Connect the plug to the power socket.
- When turning the unit on, the display shows the
temperature reading in the boiler.
Adjust the temperature as follows:
- Hold the ( + ) and ( - ) buttons pressed simulta-
neously for a few seconds;
- Press the ( + ) button to increase the temperature,
or the ( - ) button to decrease it.
It is essential that the thermo regulator is set to
190°C in order to be able to work at 10 bar.
TABLE OF COMPARISON BETWEEN DEGREES CENTI-
GRADE AND STEAM PRESSURE EXPRESSED IN BAR
° C
bar
152
5
-
159
6
max temperature of 190 °C.
165
7
-
170
8
or
175
9
180
10
described in this handbook,
contact qualified personnel at the
manufacturer or resale outlet.
- Adjustments can be made to adapt the machine
to various production requirements.
18
WARNING:
The machine is pre-set at the
For any adjustment, timing
replacement
action
not