Selects the functioning mode of the auxiliary output 1 (N.O. clean contact)
0: Open barrier light, close contact when the barrier is open, open contact when the barrier is
close, intermittent during the maneuver (fig. 15, SCA)
1: Second radio cannel of the built in receiver
2: Boom light, for controlling the LED light installed on the BOOM (DIVA3.AL), see also the
parameter LBAR.
aux1
3: Courtesy light, the contact remains close according to the parameter TLS (fig.15 SERVICE
LIGHT)
4: Photocells test, see wiring diagram in Fig.15 (PHOTOTEST)
5: Close contact with open barrier
6: Close contact with close barrier
7: Maintenance warning light. The contact closes when the number of manoeuvres set in the
Maintenance Cycle menu is reached (MACI).
Selects the functioning mode of the auxiliary output 1 (24Vdc 800 mA max.)
0: Open barrier light, close contact when the barrier is open, open contact when the barrier is
close, intermittent during the maneuver (fig. 15, SCA)
1: Second radio cannel of the built in receiver
2: Boom light, for controlling the LED light installed on the BOOM (DIVA3.AL), see also the
parameter LBAR.
aux2
3: Courtesy light, the contact remains close according to the parameter TLS (fig.15 SERVICE
LIGHT)
4: Photocells test, see wiring diagram in Fig.15 (PHOTOTEST)
5: Close contact with open barrier
6: Close contact with close barrier
7: Maintenance warning light. The contact closes when the number of manoeuvres set in the
Maintenance Cycle menu is reached (MACI).
* ATTENTION: A WRONG SETTING OF THESE PARAMETERS CAN BE DANGEROUS.
RESPECT THE REGULATION IN FORCE!
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse has no
IbL
effect during the opening phase.
Off: condominium function disabled.
The multi-flat function is enabled or disabled during the TCA counting.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter signal has no
ibca
effect during the TCA counting.
Off: the bloc of flat function is disabled.
Enables or disables rapid closing
On: rapid closure is enabled. With open bar, or in the opening phase, the activation of the pho-
SCL
tocell causes the automatic closure 3sec after the total opening of the gate. It is activated only
with TCA:ON
Off: rapid closing disabled.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
Enabled or disables HOLD-TO-RUN function
On: HOLD-TO-RUN function.
htr
The pressure of the OPENS/CLOSES button must be maintained throughout the entire manoeuvre.
The opening of the STOP input stops the motor. All the safety inputs are deactivated.
Off: Automatic/semiautomatic function
Selects the operating mode of the blinking light during the time TCA
ltca
On: Blinking light on during TCA
Off: Blinking light off during TCA
It selects the operating mode of the barrier lights (output 24Vdc AUX2 or N.O. contact of the
output AUX 1 configured with logic 2) .
On: The barrier lights are off with the barrier closed. They switch on when the barrier is in motion
lBAR
and during the opening phase.
Off: The barrier lights flash slowly (1s pause) with the barrier closed. They flash quickly (0.5 s
pause) when the barrier is in motion and during the opening phase.
It sets the BLINK flashing output operating mode.
On: The output provides intermittent voltage during the manoeuvre phase (2 flashes per second),
MBLK
to use with the LED lights of the cover.
Off: The output provides continuous voltage during the manoeuvre phase (to use with an external
flashing light)
28
14.3.3) LOGICS (LOG)
FUNCTION
0-6-(0)
0-6-(2)
ON-OFF-(Default)
MEMO
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)