Cleaning and care
ATTENTION
Before working on the appliance, switch it off and
pull out the plug of the vacuum cleaner!
Before working on the appliance, switch it off and
pull out the plug of the vacuum cleaner!
Use the device only when all filters and the filter
bag are installed.
Otherwise the motor can get damaged.
Defective filters and filters that can no longer be
cleaned must be replaced.
Replacing the filter bag
Illustration
Replace the filter bag if the filter change indicator is
on.
Illustration
Unlock and open the filter cover.
Illustration
Fold out the filter bracket and remove the filter bag.
Illustration
Close and dispose of the filter bag.
Illustration
Push the new filter bag into the support until the
stop.
Snap in the cover.
Change the motor protection filter
Motor protection filter: change before the last filter
bag is removed from the filter bag package.
The motor protection filter is behind the inserted filter
bag.
Change the motor protection filter prior to inserting
the filter bag.
Illustration
Remove the filter frame.
Remove the old motor protection filter from the filter
frame and dispose of.
Insert new motor protection filter into the filter
frame.
Insert filter frame.
Filter for pure blower air.
Note
Clean the HEPA filter in case of visible soiling.
Replace the HEPA filter in case of damage
ATTENTION
Material damage due to incorrect cleaning of the HEPA
filter.
When necessary, clean under running water only,
do not wipe or brush down.
Never clean the filter in the washing machine and
do not dry it by means of a hair dryer.
Do not wash the parts using detergents or boiling
water.
Allow the filter to dry completely before installing it
in the device (at least 24 hours).
Illustration
Open the cover.
Unlock the HEPA filter and remove.
10
HEPA filter
Illustration
Rinse the HEPA filter under cold, running water.
Shake the filter carefully after cleaning so that any
residual dirt or excess water is removed.
Allow the HEPA filter to be air-dried by light and
heat sources. Only reinstall the dry HEPA filter into
the appliance.
Illustration
Insert the HEPA filter and snap it into place.
Insert cover and snap it into place.
Cleaning the floor nozzle
Clean the reversible floor nozzle at reglular intervals!
Remove the floor nozzle from the telescopic suc-
tion pipe.
Clean floor nozzle.
Cleaning the accessories
Illustration
Handle and suction tube can be disconnected in or-
der to clean or if clogged. Push the 2 interlocks and
pull apart.
Connect handle and suction tube and insert.
Technical specifications
Type
Voltage
Current type
Protective class
Weight
(without accessories)
Action radius
Actual dust bag volume
Dimensions
Length
Width
Height
Rated power input
Vacuum min.
HEPA filter
Sound power level L
Subject to technical modifications!
EN
– 7
V
220-240 220-240
Hz
50/60
II
kg
5.1
m
7,5
l
2
mm
435
mm
288
mm
250
W
700
kPa
16
HEPA 13 HEPA 13
dB(A)
76
WA
50/60
II
5.1
7,5
2
435
288
250
700
16
76