Technical Characteristics; Introduction; Installation; To Operate Safely - Bras FBM L Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1 TECHNICAL CHARACTERISTICS

Transparent removable bowls
Capacity of each bowl, approx.
Dimensions:
width
depth
height
Net weight, approx.
Gross weight, approx.
Adjustable thermostats
Hermetic compressor
Air-cooled condenser
Overload protector
Safety pressure switch
Noise level lower than 70 dB (A)
IMPORTANT
Read electrical ratings written on the data plate of the
individual units; the data plate is adhered on the
dispensing side panel of the unit, just behind the drip
tray (the right side drip tray in multiple bowl models).
The serial number of the unit (preceded by the symbol #)
is adhered inside the left switch box. Data plate
specifications will always supersede the information in
this manual.
The electric diagram of the dispenser is located in the
inner part of the dispensing side panel.
Specifications are subject to change without notice.

2 INTRODUCTION

Please read all sections of this manual thoroughly to familiarize
yourself with all aspects of the unit.
Like all mechanical products, this machine will require cleaning
and maintenance. Besides, dispenser working can be
compromised by operator's mistakes during disassembly and
cleaning. It is strongly recommended that personnel
responsible for the equipment's daily operations, disassembly,
cleaning, sanitizing and assembly, go through these
procedures in order to be properly trained and to make sure
that no misunderstandings exist.

3 INSTALLATION

1 - Remove the corrugate container and packing materials
and keep them for possible future use.
IMPORTANT
When handling the machine never grasp it by the bowls
or by the evaporator cylinders. The manufacturer
refuses all responsibilities for possible damages which
may occur through incorrect handling.
Bras Internazionale spa
n
1
1
2
3
l
10
10
10
10
cm
18
28
36
54
cm
47
47
47
47
cm
69
69
69
69
kg
26
26
37
49
kg
29
29
40
54
n
1
1
2
3
2 - Inspect the uncrated unit for any possible damage. If
damage is found, call the delivering carrier immediately to
file a claim.
3 - Install the unit on a counter top that will support the
combined weight of dispenser and product bearing in
m i n d w h a t i s s t a t e d i n t h e p r e c e d i n g p o i n t 1
IMPORTANT warning.
4 - A minimum of 15 cm (6") of free air space all around the
unit should be allowed to guarantee adequate ventilation.
5 - Ensure that the legs are screwed tightly into the base of
the machine.
Replace the standard legs originally installed with the 100
mm (4") legs whenever they are provided with the unit.
6 - Before plugging the unit in, check if the voltage is the same
as that indicated on the data plate. Plug the unit into a
grounded, protected single phase electrical supply
according to the applicable electrical codes and the
specifications of your machine. When the unit has no plug,
install a proper grounded plug, in compliance with
electrical codes in force in your area, suitable to at least
10 Amp 250 Volt (220-230 Volts 50-60 Hz areas) and
20 Amp 25 0 Vol t (1 00-1 15 Vol ts 5 0-6 0 Hz area s)
applications. Should you prefer to connect the unit directly
to the mains, connect the supply cord to a 2-pole wall
breaker, whose contact opening is at least 3 mm. Do not
use extension cords.
ATTENTION
Failure to provide proper electrical ground according to
applicable electrical codes could result in serious
shock hazard.
7 - Each drip tray has two diaphragm plugs: if a continuous
drain is needed, perforate one of the drain plugs and
connect it to a flexible drain line (see figure 1).
8 - The unit doesn't come presanitized from the factory.
B e f o r e s e r v i n g p r o d u c t s , t h e d i s p e n s e r m u s t b e
disassembled, cleaned and sanitized according to this
h a n d b o o k
i n s t r u c t i o n s
5.3 CLEANING AND SANITAZING PROCEDURES).
IMPORTANT
Install
the dispenser so that the plug is easily
accessible.

4 TO OPERATE SAFELY

1 - Do not operate the dispenser without reading this
operator's manual.
2 - Do not operate the dispenser unless it is properly
grounded.
FBM L / LS
figure 1
( c h a p t e r
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fbm ls

Tabla de contenido