TO START THE ENGINE

Never run engine indoors or in enclosed, poor ventilated
areas, engine exhaust contains carbon monoxide, an
odorless and deadly gas.
1.
Open the fuel shut-off valve on tank and engine.
2.
Move the choke control located on the engine to "CHOKE" position.
NOTE: No choke is required on warm engines. Make sure choke is in the
"RUN" position on warm engine starts.
4.
Move the ON/OFF switch on engine to the ON position.
5.
Grasp handle on rope starter and pull slowly until resistance
is felt. Let the rope rewind slowly. Pull rope with a rapid full
arm stroke. Let rope rewind slowly. Repeat if necessary.
NOTE: IF ENGINE OIL LEVEL IS TOO LOW, ENGINE WILL
NOT START. CHECK OIL LEVEL AND ADD IF NECESSARY.
6.
When engine starts, gradually move the choke to the "RUN" position.
IMPORTANT: Allow generator to run at no load for 5 minutes upon each initial
start-up to allow engine and generator to stabilize.