2.1 Brief introduction

Amsterdam 2000 welding machines adopts the latest pulse width modulation (PWM) technology
and insulated gate bipolar transistor (IGBT) power module, which can change work frequency to
medium frequency so as to replace the traditional hulking work frequency transformer with the
cabinet medium frequency transformer. Thus its characterized with portable, small size, light weight,
low consumption and etc.

2.2 Working principle

The working principle of Amsterdam 2000 welding machines is shown as the following figure.
Single-phase 230V work frequency AC is rectified into DC(about 312 V), then is converted to
medium frequency AC (about 20-40KHz) by inverter device (IGBT module), after reducing voltage by
medium transformer (the main transformer) and rectifying by medium frequency rectifier (fast recovery
diodes),then is outputted DC .The circuit adopts current feedback control technology to insure current
output stably. Meanwhile, the welding current parameter can be adjusted continuously and steplessly
to meet the requirements of welding craft.
230V

2. 3 Welding electrodes specifications

Adjust knobs of welding current , make welding current is adequate to welding electrode
according with as following:
φ2.5
Standard
Welding current
70-100A

2.4Duty cycle

The rated duty cycle of a Welding Power Source is a statement of the time it may be
operated at its rated welding current output without exceeding the temperature limits of the
insulation of the component parts. To explain the 10 minute duty cycle period the following
example is used. Suppose a Welding Power Source is designed to operate at a 60% duty
cycle, 200 amperes at 28 volts. This means that it has been designed and built to provide
the rated amperage (200A) for 4 minutes, i.e. arc welding time, out of every 10 minute
period (60% of 10 minutes is 4 minutes). During the other 6 minutes of the 10 minute period
the Welding Power Source must idle and be allowed to cool.
29
ARC SERIES EQUIPMENT
φ3.2
φ4.0
φ5.0
110-140A
170-230A
230-280A
ARC SERIES EQUIPMENT
100
90
80
70
60
50
Safe
40
Operating
30
Region
20
10
0
0
100
120
140
160
180
Welding Current(AMPS)

2.5 Specifications

Description
Weight
size(LxWxH)
Cooling
Welder Type
European Standards
Mains voltage
Grid frequency
Welding Current Range (WIG Mode)
Effective Input Current
Maximum Input Current
Single Phase Generator Requirement
Duty cycle, 40°C, 10 min
Open Circuit Voltage
Protection Class
Insulation Class
NOTE
Due to variations that can occur in manufactured products, claimed performance, voltages,
ratings, all capacities, measurements, dimensions and weights quoted are approximate
only. Achievable capacities and ratings in use and operation will depend upon correct
installation, use, applications, maintenance and service.
Summary
200
220
240
260
280
300
320
Amsterdam 2000
6.7kg
365x160x380
Fan Cooled
Multi Process Inverter
Power Source
EN 60974-1 / IEC 60974-1
1 x 230 Volt ±15%
50/60Hz
30-200A
25 A
32A
10KVA
200A @ 60%28V
155A @ 100%26.2V
56V DC
IP23
H
30