2- While the LED is flashing, press the button on which to restore default settings 15 times.
3- The LED will flash 5 times at the end of the 15 presses.
How to restore completely default settings of a transmitter
1- Press any pushbutton on the transmitter 10 times (Configuration Menu).
The transmitter LED will flash rapidly.
2- Press one of the pushbuttons 25 times while the LED is flashing.
3- The LED will flash at the end of the 25 presses to confirm that default settings have been restored.
TRANSMITTER CONFIGURATION SUMMARY TABLE
Go to the Configuration Menu to configure a transmitter.
To do this, press any transmitter pushbutton or a pushbutton wired to the E2BPP/E4BPP 10 times: the transmitter LED will
start flashing rapidly.
Press the pushbutton to be configured the required number of times while the LED is flashing.
Number of presses
1
2
3
4
5
6
33
10
11
20
14
15
24
25
16
17
19
16
(*) The transmitter version is printed on its back.
For more information on how to create and configure a radio bus using YOKIS radio
transmitters and receivers, scan the QR code or go directly to www.yokis.com
WARRANTY: In addition to the warranty required by law, this product is guaranteed for 5 years from date of manufacture. The mate-
rial must be used according to the instructions provided and for its intended use. Faults must not be caused by deterioration or acci-
dents resulting from negligence, anomalous use or incorrect installation. In all cases, the warranty only includes replacement of faulty
products. No compensation for loss or damage may be claimed.
Customer Service: +39 011.23.39.810 - Export Dept. Phone: +39 011.24.00.250/256
DS1054-066A
Possible settings
Pushbutton operating mode
On/Off or Up/Stop/Down
Memory recall or intermediate position
On or Up/Stop
Off or Down/Stop
Radio mode
Direct mode
Radio bus mode
Use of ABE2BPP transmitter with a normally closed contact (NC button, automations, sensors,
etc.).
Product on radio bus
Lights (default configuration)
Window shutters
Lights and window shutters [V5(*) or later]
Copy or clear connections of a pushbutton or of the entire transmitter
Completely duplicate the transmitter
Restore default settings of a channel
Reset access points: delete all radio bus access points
Restore transmitter default configuration
Special functions available some modules only
Pulse mode of the contact of the MTR1300EBRP and MTR2000ERP. The receiver generates a
0.5 seconds pulse
Contact relay mode of the MTR1300EBRP and MTR2000ERP. The receiver follows the operation
of the transmitter pushbutton
MTR2000ERP and MTV500ERP flashing mode: sending of a flash control (0.5 second period for
30 seconds)
Special functions available with MAU500ER only
Timed opening
Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C
For technical information, go to www.yokis.com or call:
P11