Please clean the Cabin sensor or contact technical service
EVAPORATOR SENSOR ALARM 'PR2':
Please clean the Evaporator sensor or contact technical service
Id: Door switch alarm. If the door remains open for more than 1 minute, the alarm will start.
Close the door. If the alarm continues control the door connections or contact technical service.
IA: Indicates that there is a power outage alarm. Device warns of electricity is interrupted for a
certain time. Please contact technical service
COH: Condenser overheated alarm. Condenser reaches to the first critical temperature. Please plug
out the product. Clean the condenser and wait 30 minutes. Then restart the product again. If the
alarm continues please contact technical service.
CSd: Condenser reaches to maximum critical temperature limit. Compressor will not work in this
condition and the electrical energy of the device will be off. Please plug off the product and clean the
condenser and wait 60 minutes. Then restart the product again. If the "COH" and "CSd" alarms
continue contact technical service.
IMPORTANT WARNIING: "COH" and "CSd" alarms can also occur in where the ambient
temperature is high. Please note that in this case the ventilation of the place must be checked.
The "COH" and "CSd" alarms may lead to compressor failure and won´t covered by guarantee.
dFd: The device remains in defrost mode at the maximum duration. Please defrost the device
manually. In order to defrost manually, press and hold defrost key 4 seconds. If alarm continues
please contact technical service.
Manufacturer's settings:
To access to the procedure make sure no procedure is in progress
Touch the SET key for 4 seconds. The display will show "PA"
Touch the SET key. Then touch up and down keys within 15 seconds to set "149".
Touch the SET key or do not operate for 15 seconds. The display will show "dEF"
Touch the SET key. Then touch up and down keys within 15 seconds to set "4".
Touch the SET key or do not operate for 15 seconds. The display will show a flashing " ---" for 4
seconds, after which the device will exit the procedure.
IMPORTANT WARNING:
THE DIGITAL PARAMETER SETTING HAS BEEN PROGRAMMED FOR THE UNIT TO PERFORM THE
BEST WAY. DO NOT CHANGE ANY OF THE PARAMETER SETTING OTHER THEN SIMPLY SETTING THE
TEMPERATURE. TO CHANGE THE PARAMETERS SETTINGS CAN CAUSE SERIOUS PERFORMANCE
DECRESAES AND CREATE SERIOUS PROBLEMS IN THE UNIT.