Dust and water prevention
Safety cable
Sealing agent
Lug plate
Silica gel
Pipe
All manuals and user guides at all-guides.com
Dome cover
Sealing
agent
Seal tape
Attach the Dome cover
• Be sure that dome cover is firmly attached.
Attaching the dome improperly may cause
moisture to enter and cloud the inside or
result in the cover coming loose and fall-
ing.
• Be sure to not pinch the safety cable be-
tween the dome cover and base. Water
proof and dustproof features may not per-
form properly as aresult.
Fill using sealing agent
• Completely fill the conduit hole using seal-
ing agent. Also fill the mounting holes when
not in use.
• The sealant should be GE silicone or
equal.
• Not filling the holes completely with seal-
ing agent may cause moisture to enter,
clouding the lens and dome cover as a re-
sult. Be sure to completely close the holes.
Insert the included Silica gel
• Insert the provided silica gel in the Base
interior and hold using the lug plate.
• Always use the provided silica gel. When
not using the silica gel, the dome cover of
the camera lens may cloud as a result.
• When performing installation under rain-
ing conditions, take caution as not to al-
low rain to enter inside the unit.
• If the camera angle is not adjusted at in-
stallation, insert the silica gel inside the
unit after adjustment. The effects of the
gel diminish with prolonged exposure to
air.
• Always replace the silica gel when recon-
necting/resetting during repair or mainte-
nance.
When replacing, use:
Service parts No. LW40500-001A
Wrap seal tape (When installing the
camera to a ceiling with pipe)
Wrap the screw section of the pipe with at
least 2 rolls of seal tape.
Wrap the seal tape where the pipe-hole
screws and pipe screws meet.