4.4. WPTOUCH special status
In digital mode, you can disable a WPTOUCH (DISABLED
status) by sending the proper command from its master MIMO88. In this
status, controls are disabled, the connection icon remains lit and the
message "DISABLED DEVICE" is displayed. You can only enable the
panel from the MIMO88.
This feature can be especially useful when the installation
requires protection against unwanted tampering for some purposes or
applications, in certain time slots, etc. while on other occasions some
degree of interaction with generic system users should be allowed.
Another MIMO88 special status is the disconnected or
"UNLOCKED" status. This status is automatic when the connection
between WPTOUCH and MIMO88 is lost after connection and
synchronization via the digital bus. You can change this status only if:
•
•
12
WPTOUCH and MIMO88 are reconnected
WPTOUCH is reset (RESET), then returns to analogue
USER Mode (see Section 4.1.).