2.
The rotating wheel allows to scroll available selections.
3.
Press KEY 2 again to confirm the new selection (the one
displayed) or KEY 1 to cancel the operation. The arrow
on the far right returns to the second line of the display.
4.
If the panel is set to display the device name on line 1 of
the LCD display, it keeps showing the name of the active
source until LCD backlight turns off (after 5 seconds since
the last action on the panel controls).
If the new selection is not confirmed or cancelled while
panel is illuminated, when illumination turns off (after 5
seconds) the panel will automatically exit the selection
mode and the previous source selection will remain
active.
Choosing one or another source on the panel generates
a specific DC voltage level at its analogue control port,
suitable for this selection by the connected MIMO54.
•
Rotating wheel (JOG WHEEL): By default, in analogue
mode, it changes volume, generating the DC control
voltage suitable for MIMO54 or other equipment featuring
a 0-10V DC remote control port for volume. After pressing
KEY 1 or 2 it also has other functions such as source
selection or device configuration in EDITION and
CONFIGURATION modes.
In digital mode, functions of the panel controls depend on the
setup of the master MIMO88 (MASTER) for each panel. A MIMO88
can manage up to 16 WPTOUCH units, each one with a custom
setup to adjust some parameters of the master MIMO88. Using the
panel controls generates an exchange of data with the MIMO88
through the WPTOUCH digital port, in order for the MIMO88 to
recognize the commands, to translate them into actions and/or setup
parameter changes and provide the WPTOUCH information to be
displayed on the LCD screen (volume level, active source or memory,
etc.).. For example, in digital mode it's possible to assign the source
selection function (as in analogue mode) or the memory selection
(PRESET) to the following sequence: press WPTOUCH KEY 2 then
turn the wheel. Similarly, KEY 1 can be assigned to an output MUTE
function, cross-point of the MIMO88 audio matrix, global MUTE,
activation of a GPO control output, etc. In this mode (digital), as in
analogue mode, an asterisk appears at the far left of the LCD display
when the function assigned to that key is activated.
7