Preparation
Important: When using an existing outlet box, be sure the box is securely
attached to the building structure and can support the full weight of the fan.
Failure to do so can result in serious injury or death.
1
Step 1
Turn off circuit breakers and wall switch to the fan
supply line leads.
Warning: Failure to disconnect power supply prior to
installation may result in serious injury or death. To
reduce the risk of shock, this fan must be installed with
an isolating wall control/switch.
2
Step 2
Determine mounting method to use.
A. Downrod Mount
B. Angle Mount
Craftmade Part #45AD (see dealer)
IMPORTANT: If using the angle mount
method, check to make sure the ceiling
angle is not steeper than 35 º . Angles greater
than 35 º will require a 45 º angle adapter.
3
Check to make sure blades are at
least 30" from any obstruction.
Check downrod length to
ensure blades are at least
7' above the floor.
All manuals and user guides at all-guides.com
Downrod Installation
(Normal Ceilings)
Downrod Installation
(Vaulted Ceilings)
Step 3
84"
(2.1m)
Min.
4
Prior to securing mounting bracket, screw "J" hook (S11) into ceiling
outlet box as a secondary support means. Secure mounting bracket (#1)
to the outlet box (A) by tightening bracket screws & washers (S3) as
shown. If not mounting to an outlet box, use wood screws (S1) and
washers (S3) and mount securely to ceiling beam. Be sure at this point
to insert canopy screws (S2) in bracket.
NOTE: Do not mount directly to sheet rock or ceiling tile.
NOTE: J Hook installation is a Canadian requirement only.
"J" Hook (S11)
Ceiling
Bracket Screws
& Washers (S3)
Wood Screws (S1)
5
Step 5
Viewing Fan Housing and
Motor from top, place the
Wiring Harness wires
through the Support Arm
Nut, pulling it all the way
back to the Harness
Connector. Place the wires
through the hole in the Fan
30"
Housing and thread the wires
0.75m
through the Support Arm
Min.
and pull taut. Place the
threaded end of the Support
Arms into the holes of the
Fan Housing and secure with
the Support Arm Nuts (S9a).
Step 4
Support Beam
Outlet Box (A)
OUTLET BOX
Mounting Bracket (1)
Wood Screws (S1)
Canopy Screws (S2)
Fan Housing & Motor
Support Arm
Wire Harness
Support
Arm Nut
Harness
Connector
Light
Socket
Fan Housing