Installation

! Before operating your new appliance please read this
instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.
! Please keep these operating instructions for future
reference. Pass them on to possible new owners of the
appliance.
Positioning
! Keep packaging material out of the reach of children. It
can become a choking or suffocation hazard ( see
Precautions and tips ).
! The appliance must be installed by a qualified professional
according to the instructions provided. Incorrect installation
may cause harm to people and animals or may damage
property.
! This unit may be installed and used only in permanently
ventilated rooms in accordance with British Standard Codes
Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891
Current Editions. The following requirements must be
observed:
• The room must be equipped with an air extraction system
that expels any combustion fumes. This may consist of a
hood or an electric fan that automatically starts each time
the appliance is switched on.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
• The room must also allow proper air circulation, as air is
needed for combustion to occur normally. The flow of air
must not be less than 2 m
/h per kW of installed power.
3
The air circulation system may
take air directly from the outside
by means of a pipe with an inner
cross section of at least 100 cm
the opening must not be
A
vulnerable to any type of
Examples of ventilation holes
for comburant air.
blockages.
The system can also provide the
Adjacent
Room to be
Room
Vented
air needed for combustion
indirectly, i.e. from adjacent rooms
fitted with air circulation tubes as
described above. However, these
rooms must not be communal
rooms, bedrooms or rooms that
Enlarging the ventilation slot
between window and floor.
may present a fire hazard.
• Liquid petroleum gas sinks to the floor as it is heavier
than air. Therefore, rooms containing LPG cylinders must
All manuals and user guides at all-guides.com
Fitting the appliance
Gas and mixed hobs are manufactured with type X degree
protection against overheating. The following precautions
must be taken when installing the hob:
• Kitchen cabinets adjacent to the appliance and taller
• Hoods must be installed according to their relative
• Place the wall cabinets adjacent to the hood at a
Directly to
• The installation cavity should have the dimensions
the Outside
;
2
Hook fastening diagram
Hooking position
for top H=20 mm
also be equipped with vents to allow gas to escape in the
event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored
in rooms or storage areas that are below ground level
(cellars, etc.). It is advisable to keep only the cylinder
being used in the room, positioned so that it is not
subject to heat produced by external sources (ovens,
fireplaces, stoves, etc. ) which could raise the
temperature of the cylinder above 50°C.
than the top of the hob must be at least 600 mm from the
edge of the hob.
installation instruction manuals and at a minimum
distance of 650 mm from the hob.
minimum height of 420 mm from the hob ( see figure ).
If the hob is installed beneath a
wall cabinet, the latter must be
situated at a minimum of 700 mm
600mm min.
above the hob ( see figure ).
indicated in the figure.
Fastening hooks are provided, allowing you to fasten the
hob to tops that are between 20 and 40 mm thick. To
ensure the hob is securely fastened to the top, we
recommend you use all the hooks provided.
Hooking position
for top H=30 mm
555 mm
15
GB