SVC-10 • SVC-20
Specifications and Accuracy
SVC-10
Display: 3-digit LCD (999 maximum count)
Polarity: Automatic
Voltage Range: 1 to 700 Volts (AC or DC) and –3 to –700 Volts (DC)
Internal Basic Load: 2.1 W at 700 V (approximate)
Voltage Resolution: 1 V (AC or DC)
Accuracy (AC/DC): ± (3% of reading + 3 volts)
Frequency Range: 0 to 400 Hz
Test Current: Less than 3.5 mA
Peak Current: Less than 5 mA
Identifying Energized Conductor: 100 V to 700 V
Frequency Range: 50 to 400 Hz
Indication: Tone
Two-Probe, Three-Phase Sequence Test: 100 V to 700 V
Frequency Range: 50 to 60 Hz
Indication: Tone and
or
on LCD
Continuity Test: 0 to 100 kΩ
Test Current: 5 µA (approximate)
Indication: Tone and
on LCD
SVC-20
Display: 3-1/2-digit LCD (1999 maximum count) with backlight
Polarity: Automatic
Voltage Range: 1 to 700 Volts (AC or DC) and –3 to –700 Volts (DC)
Internal Basic Load: 2.1 W at 700 V (approximate)
Voltage Resolution: 1 V (AC or DC)
Accuracy (AC/DC): ± (3% of reading + 3 digits)
Automatic Load: For tripping a 10 mA or 30 mA GFCI
Frequency Range: 0 to 400 Hz
Test Current: Less than 3.5 mA
Peak Current: Less than 0.25 A
Non-contact Voltage Detection: 50 to 700 VAC
Identifying Energized Conductor: 100 V to 700 V
Frequency Range: 50 to 400 Hz
Indication: Tone
13