Specifications and Accuracy (cont'd)
Two-Probe, Three-Phase Sequence Test: 100 V to 700 V
Frequency Range: 50 to 60 Hz
Indication: Tone and
Continuity Test: 0 to 200 kΩ
Test Current: 5 µA (approximate)
Indication: Tone and
Resistance Range: 0 to 1999 Ω
Resolution: 1 Ω
Accuracy: ± (3% of reading + 3 Ω)
SVC-10 and SVC-20
Diode Test:
Open Circuit Voltage: 1.75 V (approximate)
Test Current: 10 µA (approximate)
Note: L1 is positive when checking diodes and continuity.
Operating/Storage Conditions: –10 °C to 55 °C (14 °F to 131 ° F)
0% to 85% relative humidity
Remove battery before storing.
Battery: 9-Volt battery (NEDA 1604, JIS 006P or IEC 6LF22)
Overvoltage Protection: Category III, 700 VAC and 700 VDC
Pollution Degree: 2
Altitude: 2000 m (6500') maximum