INSTALLATION INSTRUCTIONS
• Heater must be installed by a qualified electrician.
• Place the heater on a firm, level ceiling surface. Install the heater on a strong
support system, such as strong wooden beams, metal rails, or etc.
• The hook on the strong support system you are using to hang the ceiling
heater must be able to take a weight 3 or 4 times that of the ceiling heater
itself.
• Attach hook A (see parts diagram) to a hook on the strong support system.
Or wrap hook A around the strong support system and clip hook A onto any
ring of the chain to adjust the height of the ceiling heater.
• Make sure the distance between the bottom of the ceiling heater to the
floor must be over 70 in (180cm).
• Plug the ceiling heater into a grounded 110-120V 50-60Hz 15A power outlet.
• Only operate the heater when it is in the upright position.
CLEARANCE REQUIREMENTS
• 9.84 in (25cm) from the side wall
• 19.64 in (50cm) from the ceiling
• Installation height above 70 in (180cm)