Descargar Imprimir esta página

Care And Maintenance - Hilti TE 2000-22 Manual De Instrucciones Original

Ocultar thumbs Ver también para TE 2000-22:

Publicidad

Idiomas disponibles

Idiomas disponibles

7
Transport trolley and case B22⁄C (XL)
7.1
Transport
The transport trolley helps to ensure that the breaker can be transported safely.
Case B22⁄C (XL) ensures safe transport of charger and battery.
Take care to ensure that the transport trolley stands in a steady, secure position.
Place the product on the locating pin provided on the transport trolley and always secure it for transport
by engaging the retainer.
Place the case B22⁄C (XL) on the transport trolley and secure it with the lock.
Take care to use only safe transport routes.
Do not park the transport trolley on an incline.
Do not crane-lift the transport trolley and case B22⁄C (XL).
Push the chisels into the holders provided until they engage securely.
Take care to use only safe transport routes.
Do not park the transport trolley on an incline.
Do not crane-lift the transport trolley and case B22⁄C (XL).
8

Care and maintenance

WARNING
Risk of injury with batteries inserted !
▶ Always remove the batteries before carrying out care and maintenance tasks!
Care of the product
Carefully remove stubborn dirt.
Carefully clean the ventilation slots, if present, with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Care of the Li­ion batteries
Never use a battery with clogged ventilation slots. Clean the ventilation slots carefully using a dry, soft
brush.
Avoid unnecessary exposure of the battery to dust and dirt. Never expose the battery to high levels of
moisture (e.g. by being dipped in water or left in the rain).
If a battery has been soaked by moisture, treat it as a damaged battery. Isolate it in a non-flammable
container and consult Hilti Service.
Keep the battery free of oil and grease. Do not permit dust or dirt to accumulate unnecessarily on the
battery. Clean the battery with a dry, soft brush or a clean, dry rag.
Do not use cleaning agents containing silicone as these can attack the plastic parts.
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Maintenance
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.
Do not operate the product if signs of damage are found or if parts malfunction. Have it repaired
immediately by Hilti Service.
After cleaning and maintenance, fit all guards or protective devices and check that they function correctly.
To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare
parts, consumables and accessories approved by Hilti for use with the product can be found at your
local Hilti Store or online at: www.hilti.group.
10
English
2301753
*2301753*

Publicidad

loading

Este manual también es adecuado para:

Te 500-22Nuron te 500-22