Troubleshooting Guide - CASTLE HPS10 Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROubleShOOTINg guIDe

Unplug stove before performing any maintenance.
NeveR TeST OR CheCk eleCTRICAl COmpO-
NeNTS uNleSS STOve IS uNpluggeD fROm
pOweR Supply.
pROblem
Fault light is on
pROblem
Fault light is on
Stove beeps 10 times dur-
ing burn cycle
pROblem
Fuel not feeding
pROblem
Fuel not feeding
pROblem
Fuel not feeding
pROblem
Fire burns lazy and smoky
0
CAuSe
Fire is out
CAuSe
Overtemp
CAuSe
Main door not sealed.
No negative pressure in
fire chamber.
Piping or stove may be
plugged with ash.
CAuSe
Auger is obstructed
CAuSe
Hopper door is open
CAuSe
Stove is dirty
Check for parts online at www.castlestoves.com or call 800-345-6007 M-F 8-5 CST
WARNINg
NeveR SeRvICe OR TOuCh The feeD AugeR
wITh The STOve pluggeD IN.
NegATIve pReSSuRe IN A hOme IS A SeRIOuS
ISSue. If TheRe IS A pROblem, The STOve
ShOulD be INSTAlleD wITh A fReSh AIR kIT
(NOT INCluDeD).
SOluTION
Check fuel level in hopper.
Check auger for obstructions.
Check seals around main door.
SOluTION
Allow stove to cool, restart and check room air fan
is operating.
Check for exhaust fume obstructions.
SOluTION
The pressure sensor shuts off the feed auger when
there is no negative pressure in fire chamber.
Check door seals.
Check viewing glass seals.
Clean venting and stove through cover plate clean-
out hole.
SOluTION
Remove auger from housing and clean obstruction.
Change to a higher quality fuel.
SOluTION
Close hopper door.
Check hopper door seal.
Check if hopper safety switch is operating.
SOluTION
Clean fire pot.
Clean ash pan.
Clean exhaust vent system.
Clean stove through cover plate clean-out hole.
Operator's Manual