Information about the device
Description of the device
This device uses the principle of condensation to auto-
matically dehumidify rooms.
The fan sucks damp room air through the air inlet (8),
the air filter (9), the evaporator and to the condenser
located behind it. The air is cooled at the cold evapo-
rator until it is below the dew point. Water vapour con-
tained in the room air precipitates on the evaporator
fins as either condensation or frost. The dehumidified,
cooled air is rewarmed at the condenser and blown
out at a temperature of approx. 5 °C above room tem-
perature. The drier air which is prepared in this way
mixes with the air in the room. The humidity in the
room where the device is positioned is reduced as air
constantly circulates through the device. Depending
on the air temperature and the relative humidity, the
condensed water either drops continuously or only
during the defrost phase into the condensation tray
and through the integrated drain nozzle into the con-
densation tank (2) below. This is fitted with a float to
measure the fill level. The device has a control
panel (4) for operating and controlling the functions.
Once the maximum fill level of the condensation
tank (2) is reached, the condensation tank indicator
light (see chapter "Operating elements") on the con-
trol panel (4) flashes. The device switches off. The
condensation tank indicator light only goes out again
once the emptied condensation tank (2) is reinserted.
The condensed water can be diverted by attaching a
hose at the condensation plug (5). The device can re-
duce the relative humidity of a room by up to approx.
30 %. It provides additional assistance for drying wet
washing or clothing in living or working spaces. Be-
cause of the heat radiation which is tied up in opera-
tion, the room temperature can rise by approx. 1-4 °C.
B - 2
All manuals and user guides at all-guides.com
Device depiction
No.
1
2
3
4
5
6
7
8
9
Operating Manual – Dehumidifier TTK 25 E
4
3
2
8
7
Operating element
carry handle
condensation tank
air outlet
control panel
condensation plug
feet
power cable
air inlet
air filter
1
5
6
9
EN