Status
All LEDs show in sequence, fol-
lowed by one (1) LED showing con-
stantly red.
4
Technical data
Weight without battery
Single impact energy in accordance with EPTA pro-
cedure 05
Drilling diameter range in concrete/masonry (ham-
mer drilling)
Ambient temperature for operation
Storage temperature
4.1 Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
5
Preparations at the workplace
WARNING
Risk of injury by inadvertent starting!
▶ Before inserting the battery, make sure that the product is switched off.
▶ Remove the battery before making any adjustments to the power tool or
before changing accessories.
*2266025*
Meaning
If a connected product can still be
used, the remaining battery capac-
ity is below 50 %.
If a connected product can no
longer be used, the battery has
reached the end of its useful life
and has to be replaced. Consult
Hilti Service.
2266025
2.3 kg
(5.1 lb)
1.5 J
3/16 in ... 5/8 in
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 70 ℃
(−4 ℉ ... 158 ℉)
21.6 V
See the end of
these operating
instructions
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 40 ℃
(−4 ℉ ... 104 ℉)
−10 ℃ ... 45 ℃
(14 ℉ ... 113 ℉)
English
11