IMPORTANT PARTS - FIGURES 2 & 3
1. Keypad/LCD Display (refer to Figure 5 for LCD
symbol definition)
2. Outlet Port
3. Carrying Case
4. Air-Inlet Filter
5. DC input connector (model 9001 only)
6. AC Power Connector
7. DIN connector
8. Power Cord (assure proper configuration for outlet)
ACCESSORIES/REPLACEMENT ITEMS—FIGURE 4
1. CPAP Humidifier
F & P Humidifier (not shown)
2. DeVilbiss Serenity™ Mask
(One size fits all. Includes headgear.)
Nasal CPAP Masks (not shown)
Small
Medium
Medium/Small
Large
3. Air-Inlet Filter(4/pk)
4. Optional Fine Particle Filter
5. Oxygen Adapter
6. DeVilbiss Seal-Ring™ (4/pk) (not shown)
Small
Medium or Medium/Small
Large
7. 6' 22 mm Tubing
8. Strap-Style Headgear (not shown)
9. Cap-Style Headgear (not shown)
10. Optional 12V DC power
cord (9001 only)
Ask your Sunrise Medical provider for information about
other DeVilbiss mask styles and sizes.
A-900
All manuals and user guides at all-guides.com
I m p o r t a n t P a r t s
1
2
Figure 2
5
7
9100D
HC105
9352D
6
8
9351D-668
Figure 3
9351D-669
9351D-667
9351D-670
2
8000D-602
8000D-603
7353D-601
9351D-658
7
4
9351D-659
3
10
9351D-660
Figure 4
7351D-616
7351D-617
7351D-627
7304D-619
S e t - u p / O p e r a t i o n
SET-UP FOR 9000/9001
This is not a life support device and is
3
intended to be used on spontaneously
breathing adults.
NOTE—Refer to Important Parts for part identification.
• Place unit on level, sturdy surface away from
heating vents, radiators, drapes and bedspreads
so that air intake is not restricted.
• Insert the appropriate power cord into the AC
power connector (Figure 3).
• Plug the power cord into an appropriate wall
outlet. The display will show Set Pres and CPAP
will increase to the prescribed pressure.
• Refer to Figure 5 for LCD symbol definitions.
• Connect the 6-foot length of 22 mm diameter
4
tubing to the outlet port on the front of the unit
(Figure 6). This is the port from which CPAP air
supply is provided.
• Connect the opposite end of the 22 mm tubing
to the mask and headgear assembly.
1
NOTE—Excess facial oils will deteriorate mask material.
To prolong mask life, wash face nightly before
wearing mask.
NOTE—Some tubing is prone to kinking. Flow can be
5
blocked causing apnea episodes to resume. Use
only 22 mm diameter smooth bore-type, kink-
resistant tubing.
• Position mask loosely on face. Adjust headgear
straps so mask is snug and comfortable (Figure 7).
OPERATION OF THE 9000
CO
Rebreathing
2
CO
rebreathing is minimized during use by providing
2
3cmH
O minimum pressure, which creates airflow
2
through mask vent holes. It is important that mask
vent holes are not blocked.