Maintenance And Care; Troubleshooting; High Pressure Connection - Kärcher K 3 Manual Del Usuario

Ocultar thumbs Ver también para K 3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 61
Frost protection
Caution
Protect the appliance and its ac-
cessories against frost.
The appliance and its accessories can
get destroyed through frost if there is
any water residues in them. To avoid
damage to them:
Completely drain all water from the
appliance: Switch the appliance on
with detached high pressure hose
and detached water supply (max. 1
minute) and wait, until no more wa-
ter exits at the high pressure con-
nection. Turn off the appliance.
Store the appliance and the entire
accessories in a frost free room.

Maintenance and care

Danger
Turn off the appliance and re-
move the mains plug prior to any
care and maintenance work.
Prior to longer periods of storage, e.g.
in the winter:
Remove filter from suction hose for
detergent and clean under running
water.
Pull out the sieve in the water con-
nection using flat-nose pliers and
clean under running water.
Maintenance
The appliance is maintenance free.
Spare parts
Use only original KÄRCHER spare
parts. You will find a list of spare parts
at the end of these operating instruc-
tions.
24
Care

Troubleshooting

You can rectify minor faults yourself
with the help of the following overview.
If in doubt, please consult the author-
ized customer service.
Danger
Turn off the appliance and re-
move the mains plug prior to any
care and maintenance work.
Repair works may only be per-
formed by the authorised cus-
tomer service.
Appliance is not running
Pull on the lever of the trigger gun;
the device will switch on.
Check whether the voltage indicat-
ed on the type plate corresponds to
the voltage of the mains supply.
Check the mains connection cable
for damages.
Pressure does not build up in
the appliance
Check setting at the spray lance.
Appliance ventilation: Switch the
appliance on with the high-pressure
hose detached and operate (max. 2
minutes) until the water exits the
high-pressure connection without
bubbles. Switch off appliance and
reconnect high-pressure hose.
Check the water supply.
Pull out the sieve in the water con-
nection using flat-nose pliers and
clean under running water.
Strong pressure fluctuations
Clean high-pressure nozzle: Re-
move dirt and debris from the noz-
zle bore, using a needle and rinse
through with water from the front.
Check water flow quantity.
EN