Carel DryClim Serie Hoja De Instrucciones página 13

Deshumidificador prâctico y compacto
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Condensate collecting tank
When the water reaches the maximum level in the condensate collection tank, the dehumidifier stops and the red pilot light (2) on the control panel
switches on. The tank can be extracted by first opening the front door of the appliance. The tank is emptied by sliding open the door at the top of
the tank. Once the tank has been emptied, it is important to remember to close the door since it prevents the water from flowing out of the tank
when the latter is moved or when the dehumidifier is moved. To restart the appliance the tank must be put back into its lodging and this door also
closed.
Besides indicating that the condensate collection tank is full, the red pilot light (2) also indicates when the tank is missing or inserted badly.
As long as the red pilot light (2) is on, the appliance cannot operate at all.
The water can also be drained continuously by connecting a rubber hose with an internal diameter of 10 mm to the connector found under the tank.
The hose will leave the appliance through the hole on the dehumidifier bottom. Check that the hose drains properly.
Rules for installation
• The dehumidifiers of the DryClim series are simply placed in the room to be dehumidified and started. To obtain maximum efficiency keep to the
following rules:
• make sure that in the room, where the dehumidifier is installed, the conditions never exceed the working limits of the machine (tab.1);
• the room where the dehumidifier is installed must be closed;
• the appliance must always operate in a vertical position with the four wheels turned downwards;
• the dehumidifier must be placed so that the air intake and outlet grids are left free (at least 10 cm air space);
• make sure that the power supply voltage corresponds to that indicated in tab. 2 and that the electrical installations comply with the regulations in
force;
• it is advisable to place the dehumidifier in the coldest point of the room where humidity normally collects.
Positioning
The dehumidifier is moved on the floor on its swivel wheels. It is advisable to install the dehumidifier near an electricity output socket.
Start-up (B)
Plug the appliance into a 230V, 50Hz grounded socket, and turn the humidistat knob (13). The different positions of the knob allow obtaining
different degrees of dehumidification according to the data shown in Tab.2.
Position
Degree of relative humidity obtainable
Off
/
1
between 80% and 65%
2
between 65% and 50%
3
between 50% and 40%
Continuous
40%
Maintenance
The dehumidifiers of the DryClim series need no particular maintenance. It is advisable to dust them and keep the air intake and outlet grids clean.
Contact your dealer if it should function badly or break down. The power supply cable has an M type connection; in the event of damages, an
original replacement cable must be used (see the exploded view with references for spare parts).
Before doing anything on the appliance disconnect the power supply by unplugging the machine.
Storage
• Keep the appliance in a room with a temperature between –25°C and +55°C.
• When the appliance is still packed keep to the instructions on the box.
• Do not place other heavy material on the box.
Check-up to carry out before and after a long period of inactivity
Before
• Disconnect the plug and empty the condensate collection tank;
• cover the machine to protect it from dust.
After
• The fan must turn freely without gripping;
• put the machine working following this manual's instructions.
DryClim +030221735 - rel. 3.0 - 01.04.2008
All manuals and user guides at all-guides.com
(Fig. 1)
Example of environment
/
Cellars and basements, uninhabited rooms
Rooms used by people
Laundry rooms, places where a reduced degree of humidity is needed
/
7
ENG
Tab.2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dryclim 13Dryclim 21Dryclim 27

Tabla de contenido