The sum of the leakage current of the Zenergy and the connected equipment
o
should not exceed 3.5 mA.
Make sure that the connected load does not exceed the power of Zenergy
o
Station: to ensure improved backup time, we recommend a load equivalent to
1/3 of nominal UPS protected outlets.
Zenergy Station is designed to protect computers or hi-fi devices: it is not
o
made for use with products such as engines, fluorescent lights, nor resistive
loads.
Do not connect Zenergy Station to medical healthcare devices, nor microwave
o
ovens or vacuum cleaners.
Due to excessive consumption, do not connect any laser printer on backup
o
time protected outlets, but only on surge protected outlets.
About batteries:
Qualified technicians are recommended to change the battery.
o
Do not dispose of the battery in a fire as it may explode.
o
Do not open or mutilate the battery. Released electrolyte is harmful to the skin
o
and eyes. It may be toxic.
Battery circuit is not isolated from AC input; hazardous voltage may exist
o
between battery terminals and ground.
A battery may cause an electric arc and high short circuit current. The
o
following precaution should be observed when working on batteries:
4 . S T O R A G E I N S T R U C T I O N S
Install the Zenergy Station in any protected environment that provides adequate airflow
around the unit, free from excessive dust, corrosive fumes and conductive contaminants. Do
not place your Zenergy Station in an environment where the ambient humidity is high.
Storage temperatures above 20°C should be avoided as this will significantly shorten battery
life.
The Zenergy Station should be stored with its battery fully charged. Batteries kept in storage
should be recharged every 3 months: failure to do so could result in battery damage. This is
done by leaving it connected to the mains power supply for 24 hours.
INFOSEC UPS SYSTEM - 4, rue de la Rigotière – 44700 Orvault – FRANCE - www.infosec.fr
Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr - 10 04 04 206 13
All manuals and user guides at all-guides.com
Remove watches, rings or other metal objects from hands.
Use tools with insulated handles.
Do not lay tools or metal parts on top of batteries.
Disconnect charging source prior to connecting or disconnecting
batteries terminal.
In order to replace the batteries, use the same number and type
of sealed lead-acid batteries.
3