FW 3000
Problem
Cause
Low air output
The air filter is obstructed.
The heat exchange coils are polluted.
The internal blower is defective.
Water enters the
The condensation water drainage openings
vehicle
are clogged up.
The seals are damaged.
Under-bench air
No supply voltage (230 Vw) connected.
conditioner
The voltage is too low (under 200 Vw).
does not switch
The voltage converter is defective.
on.
The defective thermal protection is defective.
The electrical fuse of the power supply is too
low.
Under-bench air
The air filter is obstructed.
conditioner
The voltage is too low (under 200 Vw).
stops working.
The voltage converter is defective.
The defective thermal protection is defective.
The condenser fan is damaged.
The heat exchange coils are polluted.
The external blower is defective.
Under-bench air
One of the temperature sensors is defective.
conditioner
does not switch
off.
9
Disposal
Regulations for environmental safety and correct disposal
All organisations must apply a set of procedures to identify, evaluate and control the influence that their activities
(manufacturing, products, services, etc.) have on the environment.
The procedures to be followed to identify significant environmental impact must take the following factors into
account:
• use of raw materials and natural resources
• atmospheric emissions
• discharge of liquids
• waste management and recycling
• contamination of the soil
In order to minimise environmental impact, the manufacturer provides a series of indications here below that
should be taken into account by all those who, for whatever reason, interact with the appliance during its working
life.
EN
Remedy
➤ Clean the air filter.
➤ Contact an authorised workshop.
➤ Clean the drainage openings for con-
densation water.
➤ Contact an authorised workshop.
➤ Check the power supply.
➤ Contact an authorised workshop.
➤ Check the electrical fuse of the power
supply.
➤ Clean the air filter.
➤ Contact an authorised workshop.
➤ Contact an authorised workshop.