TROUBLE SHOOTING
1. Please note, if a power failure occurs due to disconnection of the power cord, or the power
button has been pushed off during an ice making cycle, small ice chips may be formed and
lodge in the automatic shovel causing it to jam. If this occurs, the ice chips may be removed by
disconnecting the power cord and gently pushing the shovel to the rear of the cabinet and
removing the ice chips, then restarting.
2. Please check if the water reservoir is flat when the ice shovel cannot remove the ice-to-ice
basket. If not, please push the ice shovel gently by finger, then press "
PROBLEM
The compressor works
abnormally
with
Buzzing noise.
Water
shortage
indicator light is on.
Indicator
lights
display are not on
The Ice made is too
large and with pieces
sticking together.
The ice making process
was correct, but no ice
came out?
All indicators flash at
the same time.
The machine has been
working, but the water
has been warming
When the ice is full, the
machine
does
display the ice full Icon
POSSIBLE CAUSE
The voltage is lower than
a
recommended
1. There is no water
2. The pump is full of air
on
No power
1. Wrong ice size selected
2. Ice of previous cycles left in the
water tray
1. The compressor has no
refrigerant
2. Compressor damaged
3. Fan motor damaged
1. The water box is blocked by ice.
2. The motor is stuck, or the motor
falls off, or the motor is damaged.
3. Micro switch damaged.
Solenoid broke down
Ice full sensor damaged
not
Solar light interference
" button to restart.
SUGGESTED SOLUTIONS
Stop the Ice maker and do not restart
until the voltage is normal.
1. Add to some water until it reaches
MAX position.
"
"
2. Press
button to restart.
Turn power on
1. Select small size.
2. Take out the ice under the standby
state.
Call the technical service
1. Take out the ice under the ice
shovel, plug in the power again,
"
and press the
minutes, the machi ne will restart
automatically.
2. Call the technical service.
Replace the solenoid valve
1. Replace the ice full sensor
2. Move indoors to make ice
3. Call the technical service.
"
button. After 3