BFT SHYRA AC SL Instrucciones De Instalación página 10

Cuadro de mandos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 21
TABLE ERR
Unlit
Internal system supervision control error
Lit
- Try switching the card off and on again or
press the S2 button. If the problem persists
contact technical assistance.
Test hardware card error
slow
- Check the connection to the motor
flashing
- Hardware problems to the card (contact
technical assistance)
Terminal
L
N
10
11
12
20
21
41
42
43
50
51
52
60
61
62
10 -
SHYRA
INSTALLATION MANUAL
Lit
Definition
LINE
NEUTRAL
START + CONDENSER
COM
START + CONDENSER
AUX 0 – POWERED CONTACT
230V (N.O.) (40W MAX)
+REF SWE
SWC
SWO
0V-
24V+
24 Vsafe+
Common
START
OPEN
Led ERR
slow flashing
Photocell test,
Costa o Costa 8k2 failed
- Check photocell connection and/or logic
settings
Single-phase power supply
Motor and condenser connection
Exit due to FLASHING LIGHT
Contact stays closed while leaves are operating.
Limit switch common
Closing limit switch SWC (N.C.)
Opening limit switch SWO (N.C.)
Accessories power supply output.
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output act ive only during operating cycle.
START and OPEN inputs common
SHYRA AC SL
START command button (N.O.).
Operation according to "Residential / apartment building operation" logic
SHYRA AC BA
If trimmer T2 at maximum:
START command button (N.O.).
Operation according to "Residential / apartment building operation" logic
If trimmer T2 at minimum:
CLOSE command button (N.O.).
The command causes the device to close. If the input stays closed, the leaves stay open until
the contact is opened.
OPEN command button (N.O.).
Gate opened with this command. If the input stays closed, the leaves stay open until the
contact is opened.
When the contact is open, the automated device closes following the TCA time, where
activated.
fast flashing
Limit switch error
- check connections of the limit switches
Changed settings and/or Operating logics
press S2 for 5s to confirm.
Description

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Shyra ac sl 120Shyra ac baShyra ac ba 120

Tabla de contenido