CS.W110.IST-1 / Rev 1.3
Switch-off cycle
Pressing key 3 (On/Off) on the remote control or key 1 (On/Off) on the support panel, will switch off the appliance. The display will show "SWITCHING
OFF". The pellet loading stops and the flue gas extractor speed increases to maximum and then switches off after the cooling of the appliance,
displaying "OFF". During this stage the brazier is emptied and cleaned.
Modifying the main room temperature Setting
-
To modify the room temperature, simply select "SET ROOM" by pressing button 1 (Increase).
-
Press keys 1 and 2 (Increase and Decrease) to adjust the value and confirm by pressing key 4 (Set) or 5 (Esc); values between 07°C and 40°C
can be set.
-
Pressing key 3 (On/Off) or waiting a few seconds without confirming will mean that the set value is not saved.
During this operation, the display will appear as in the following picture:
During the working mode, the appliance enters economy mode operation - "MODULATION" when that temperature value is reached (See "Working
mode").
Modifying the power Setting
-
To modify the working power you must select "SET POWER" by pressing key 2 (Decrease).
-
Press keys 1 and 2 (Increase and Decrease) to adjust the value and confirm by pressing key 4 (Set) or 5 (Esc); power values between 1 and 5
can be set.
-
Pressing key 3 (On/Off) or waiting a few seconds without confirming will mean that the set value is not saved.
During this operation, the display will appear as in the following picture:
Modify ducted air speed Set values
-
To modify the speed of the ducted air fans (1 or 2 according to the model), select"SET DUCTING" by pressing key 5 (Esc).
-
Press key 2 (Decrease) to modify the value for the ducted air fan for zone 1 and confirm by pressing key 4 (Set) or 5 (Esc); the value can be set
manually from 1 to 5, or set to automatic (A) connected with the value set in "SET POWER"
-
Press key 1 (Increase) to modify the value for the ducted air fan for zone 2 and confirm by pressing key 4 (Set) or 5 (Esc); the value can be set
manually from 1 to 5, or set to automatic (A) connected with the value set in "SET POWER"
-
Pressing key 3 (On/Off) or waiting a few seconds without confirming will mean that the set value is not saved.
(see "Modifying the power Setting").
(see "Modifying the power Setting").
20
SET ROOM
(Room temperature for the main
room, can be set at values
between 07°C and 40°C)
POWER SET
(Working power values between
1 and 5 can be set.)
ENGLISH