Before Commissioning; Assembly - Scheppach DP55 Traducción Del Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
* After an uninterrupted operating period of 5 minutes,
the device should be allowed to rest until its tempera-
ture has dropped to within 2 K (2° C) of room temper-
ature.
The workpiece must have a minimum height of
3 mm and a minimum width of 45 mm. Make sure
that the workpiece is always secured with the
clamping device.
Noise
Sound and vibration values were measured in accord-
ance with EN 62841.
Sound pressure level L
pA
Uncertainty K
pA
Sound power level L
WA
Uncertainty K
WA
Wear ear-muffs.
Excessive noise can result in a loss of hearing.
The above-mentioned noise emission values were
measured in accordance with a standardised test pro-
cedure and can be used to compare one power tool
with another.
The specified device emissions values can also be
used for an initial estimation of the load.
Warning:
• The noise emission values can vary from the speci-
fied values during the actual use of the electric tool,
depending on the type and the manner in which the
electric tool is used, and in particular the type of
workpiece being processed.
• Try to keep the stress as low as possible. For ex-
ample: Limit working time. In doing so, all parts of
the operating cycle must be taken into account (such
as times in which the electric tool is switched off or
times in which it is switched on, but is not running
under a load).
7.

Before commissioning

• Open the packaging and carefully remove the de-
vice.
• Remove the packaging material as well as the pack-
aging and transport bracing (if available).
• Check whether the scope of delivery is complete.
26 | GB
• Check the device and accessory parts for trans-
port damage.
• If possible, keep the packaging until the expiry of
the warranty period.
ATTENTION
The device and the packaging are not children's
toys! Do not let children play with plastic bags,
films or small parts! There is a danger of choking
or suffocating!
Before connecting the machine, make certain that the
data on the type plate matches with the mains power
data.
• Check the device for transport damage. Immediate-
89.6 dB(A)
ly report any damage to the transport company that
3 dB
delivered the electrical tool.
102.6 dB(A)
• Long supply cables (extension cable) should be
avoided.
3 dB
• Do not operate the electrical tool in damp or wet ar-
eas.
• Operate the electrical tool only in suitable areas
(well ventilated).

8. Assembly

m Attention!
Always make sure the device is fully assembled before
commissioning!
m Before connecting the machine to the mains power,
make certain that the data on the type plate matches
with the mains power data.
m Warning! Always pull out the mains plug before
carrying out adjustments on the device.
8.1 Assembling the base plate and column (fig. 2)
1.
Slide the quick clamp (2) over the column (3).
2.
Set the column (3) into the base plate (1) such that
the guide pins on the bottom end of the column (3)
engage with the groove in the mount on the base
plate (1).
3.
Tighten the pre-assembled fastening screws (A)
on the rear of the base plate (1) with the Allen key
(L).
8.2 Fitting the parallel stop (fig. 3)
1.
Slide the parallel stop (16) into the grooves in the
base plate (1).
www.scheppach.com

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

5906822901

Tabla de contenido