PROGRAMMING
EN
Factory settings
The followings are the values of the default
factory settings, if you need to change them
follow the instructions in the next paragraphs.
- User Address=100
- Internal address=000
- User additional addresses (1-4)=empty
- Common internal address=empty
- Address associated with Button 1=empty
- Address associated with Button 2=empty
- Address associated with Button 3=empty
- Address associated with Button 4=empty
- Address associated with Button 5=empty
- Address associated with Button 6=empty
- Send A1/GN input=disabled
- GC-GE contacts=activated by external door
station call
- Door open signalling=only if intended for
own address
- Muting of all ringtones=press button 2 for
more than 4 sec.
- Call tones and number of rings=table1
Table 1.
Factory settings for ringtones
Number Type of
Calls
of rings melody
from door station
1
intercommunicating 4
from other users
4
floor (local)
1
Programming via Bluetooth
It is recommended to program the device via
Bluetooth by downloading the "DUO System"
app (available for iOS and Android) in your
smartphone or tablet. This requires:
connect a PGR2991BT or XE2921 Bluetooth
programmer to the system;
launch the DUO System app, go to the Bus
DUO section, press the "+" button and enter
the intercom address (100 by factory defaults);
program and disconnect.
If a Bluetooth programmer cannot be
used, an "emergency" programming
procedure is available, described in the
following paragraphs.
Entering programming mode
Programming is only possible when the inter-
com is in standby mode. To enter programming
mode:
hold pressed button
for 4 seconds with
the handset on hook;
after the 4 sec. the intercom emits a tone;
keep button
pressed and unhook the
handset. The yellow LED turns on and stays
on for the whole programming phase. Re-
lease button
.
Exit programming mode
To exit programming, you need to:
hang up the handset;
yellow LED turns off.
Attention: If no operations are carried
- 10 -
Mi 2401/1
out for more than 60 seconds, the
intercom exits the programming mode
automatically.
Quick programming of user address.
With the programming described above, it is
possible to store the the intercom address
from the external station. To enter the quick
programming mode you must:
enter the programming mode following
the instructions described in "Enter the
programming phase";
make a call from an external station
within 2 minutes: press the button you want
to assign to the user on the push-button
keyboard. When the call is received, the
intercom is programmed automatically you
hear the call tone in the handset. Close and
pick up the handset to start a conversation
with the external door station and check
the correct operation of the system;
programming mode is signalled on the
external door station by an acknowledge
tone if accepted or a dissuasion tone if
rejected.
Entering codes and values
To enter codes and values, use the keys 1, 2
and
; their use is as follows:
: Press this button to confirm the
entering of a code or to switch to next
programming phase.
2:
Press this button to increase the value
Din-Don
of the digit to be entered. Press the
button a number of times equal to the
Dring 1
digit to be entered (digit 1=1 press, digit
Dring 2
9=9 presses, digit 0=10 presses of the
Dring 3
button).
1:
Press this button to confirm the digit
entry and move on to the next entry.
Press the button to move from hundreds
to tens, from tens to units and to confirm
the entry of units.
Each button pressing is confirmed by a tone.
Notes on entering codes and values
- The codes and values to be entered must be
always composed by three digits (hundreds,
tens, and units); codes and values that are
composed of tens and units or units alone
must be completed by adding zeros. For
example, number 96 becomes 096 and
number 5 becomes 005.
- The digits must be entered one by one by
pressing button "2" as many times as the
value to be entered, followed by pressing
button "1" to move on to the next digit (a tone
will indicate when to move on to the next
digit). For example, to enter number 096 you
need to:
- press the "2" button 10 times to enter the
digit 0 and then press the "1" button;
- press the "2" button 9 times to enter digit
9 and then press the "1" button;
- press the "2" button 6 times to enter the
digit 6 and then press the "1" button.
Table 2 (programming phases)
Button to press
---------------------------------------------
> 4 sec.
---------------------------------------------
Button 1 > 4sec
Button 2 > 4sec
Button 3 > 4sec
Button 4 > 4sec
Button 5 > 4sec
Button 6 > 4sec
---------------------------------------------
-----------------------------------------------
Programming procedure
To carry out the programming, you need to:
Enter the programming mode as described
in the "Enter Programming Mode" section;
identify the programming buttons to press
(see table 2);
press the buttons relating to the
programming phase as shown in table 2;
the yellow LED will start flashing;
enter the new value, following the
instructions in the "Entering Codes and
Values" section;
press
the yellow LED returns on and stays on;
continue with another programming or
exit, following the instructions in the "Exit
Programming Mode" section.
User address and internal address.
Assign user address (factory setting 100, per-
mitted addresses 001-200) and the internal
address used to identify the device within the
flat (factory setting 000 -MASTER, permitted
addresses between 000 and 006). To program
the user address and internal address it is
necessary to:
after entering in programming mode,
enter the programming mode following
the instructions described in "Enter the
programming phase";
keep pressed the button
4 seconds; yellow LED starts flashing;
enter the 3 digit of the user address following
the procedure reported on the paragraph
"Entering codes and values";
press the button
to the next phase which is: programming of
the internal address; an acknowledge tone
will be heard;
enter the 3 digit of the internal address
following the procedure reported on the
paragraph "Entering codes and values";
press the button
edge tone will be heard and the yellow LED
lights-ON continuously;
proceed with another programming phase
or exit the programming phase by hanging
up the handset.
Note. If one of the two above mentioned
addresses is already correctly programmed
and you don't want to program it again it is
possible to skip it by pressing button
Programming of additional addresses
and common internal address.
In DUO systems, the intercom can also answer
calls addressed to other users, so 4 addition-
al call addresses can be stored. The storage
procedure is shown below:
parameter to configure
after entering in programming mode,
enter the programming mode following
User address and internal
the instructions described in "Enter the
address.
programming phase";
keep pressed the button
Button 1 address.
4 seconds; yellow LED starts flashing;
Button 2 address.
again keep pressed the button
Button 3 address.
more than 4 sec.; yellow LED starts quickly
flashing;
Button 4 address.
Button 5 address.
Button 6 address.
> 4 sec.+
> 4 sec. Additional addresses.
> 4 sec.+ Button 1 > 4 sec. A1 re-send.
to confirm: you will hear a tone,
for more than
to confirm and move
to confirm; an acknowl-
for more than
.
for