Technical Data - Hansgrohe AXOR Starck 10415 Serie Instrucciones De Montaje

Ocultar thumbs Ver también para AXOR Starck 10415 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
Attention! The fitting must be installed, flushed and
tested after the valid norms.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water,
swivel to the right = cold water.
The flow is changed from bath to shower function
by pulling the knop at the upper side of the spout.
After shutting off the water flow, the mixer returns
automatically to the bath function.

Technical Data

Operating pressure:
Recommended operating pressure: 0.1 - 0.5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow 0.3 MPa:
Test certificate:
10415XXX/17415XXX/
35425800/37455XXX:
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0.15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 27.
Don't install a hot-water-barrier in combination with
flow-heater!
Install the ibox always above the bath-tup. If parts of
the ibox will broken, the water can flow in there!
Maintenance
10417XXX/17417XXX/18457000/35427800/
37417XXX: The safety device must be checked
regularly according to DIN EN 1717 in accordance
with national or regional regulations (at least once
a year).
English
Spare parts (see page 3)
1
1.1 screw cover
2
3
4
4.1 screw cover
5
5.1 screw cover
6
7
8
9
10
max. 1 MPa
11
12
1.6 MPa
13
14
max. 80° C
15
65° C
16
approx.
17
30/24 l/min
18
19
20
WRAS
21
22
23
24
25
26
27
28
XXX = Colors
000 chrome plated
090 chrome plated/gold optic
120 chrome plated/porcelain colour
800 stainless steel optic
810 satinox
handle Starck
handle Carlton
handle Massaud
handle Steel
handle Terrano
face plate
face plate Massaud
flange
flange Massaud
flange Terrano
locking screw for handle
cartridge cpl.
nut
o-ring 13x2
noise reduction(2)
selector assy
sub plate
fixing screw (4)
sleeve
diverter knob Starck
diverter knob Carlton /Terrano
diverter knob Massaud
diverter knob Steel
non return valve
vacuum breaker
extension 25 mm
extension 22 mm
extension 22 mm Massaud
10492XXX
96338000
17092XXX
18492000
35093800
96681000
37491XXX
96347000
96453XXX
98733000
95010XXX
98684000
96348XXX
96059000
92730000
95007000
98128000
94073000
95014000
96447000
96454000
96448XXX
96934XXX
95013XXX
96473000
96731800
96655000
96753000
13595000
13596XXX
97407000