Connect the supply hose(minimu length 7.5
m, minimum diameter 1/2") to the water
connection point of the machine and at the
water supply point (for e.g. a tap).
Note: The supply hose is not included.
Suck in water from vessel
Connect suction hose (minimum diame-
ter 1/2") with filter (accessory) to the
water connection point.
Max. suck height: 0.5 m
–
Danger
Never suck in water from a drinking water
container. Never suck in liquids which con-
tain solvents like lacquer thinner, petrol, oil
or unfiltered water. The sealings within the
device are not solvent resistant. The spray
mist of solvents is highly inflammable, ex-
plosive and poisonous.
Power connection
For connection values, see technical
–
data and type plate.
The electrical connections must be
–
done by an electrician according to IEC
60364-1.
Set the appliance switch to "0/OFF".
Plug in the main plug.
Danger
Danger of injury by electric shock.
Unsuitable extension cables can be
–
hazardous. Only use extension cables
outdoors which have been approved for
this purpose and labelled with a suffi-
cient cable cross section:
Always unwind extension lines com-
–
pletely.
The plug and coupling of the extension
–
cable used must be watertight.
Caution
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
20
Danger
Risk of explosion!
Do not spray flammable liquids.
Caution
Never operate device with empty fuel
–
tank The fuel pump will otherwise be
destroyed. This also applies to cold wa-
ter operation.
Risk of damage! Never operate the ap-
–
pliance without a filter in the water con-
nection.
Risk of damage! Do not place any objects
–
(hose,etc.) on or over the chimney.
Device with hose drum:
–
Always unwind high pressure hose
completely
Safety instructions
Warning
Long hours of using the appliance can
cause circulation problems in the hands on
account of vibrations.
It is not possible to specify a generally valid
operation time, since this depends on sev-
eral factors:
Proneness to blood circulation deficien-
–
cies (cold, numb fingers).
Low ambient temperature. Wear warm
–
gloves to protect hands.
A firm grip impedes blood circulation.
–
Continuous operation is worse than an
–
operation interrupted by pauses.
In case of regular, long-term operation of
the device and in case of repeated occur-
rence of the symptoms (e.g. cold, numb fin-
gers) please consult a physician.
Open/close the hood
Illustration
Unlock the hood lock using a screwdriv-
er, pivot the appliance hood forward
and unhook it.
Illustration
Hook in the appliance hood (see ar-
rows), pivot it up and lock in the hood
lock.
– 4
EN
Operation