8. Mount the filter holder together with the
filter in the same way as it was installed
at the factory.
Cleaning evaporator
ü The evaporator must be de-iced and
dry.
1. Switch off the device at the device switch
and disconnect the power plug.
2. Remove the housing cover and place it
on the ground.
3. Clean the cooling coils from both sides
with compressed air.
To remove greasy dirt from the cooling coils,
proceed as follows:
1. Clean the condensate tray under the
cooling coils as well as the drain hose.
2. Spray the cooling coils with a mild deter-
gent solution, using a spray bottle.
3. Let the cleaned components dry.
4. Mount the covers in the same way as
they were installed at the factory.
ð You have now cleaned the evaporator.
Cleaning pump sump
Depending on the way the device is used,
deposits may form in the pump sump. To
clean the pump sump, proceed as follows:
1. Switch off the device at the device switch
and disconnect the power plug.
2. Remove the housing cover and place it
on the ground.
10
Illustration 3: Removing condensate tank
1
Condensate
tray
3
Housing
5
Fixture of
condensate
pump
3. Disconnect the condensate hose from
the condensate pump.
4. Loosen the two securing screws of the
condensate pump and slide the pump to
the side to remove it from the device.
The connecting cable is sufficiently long
to remain attached to the device.
5. Clean the condensate pump with a damp
cloth and a mild detergent.
6. Replace the condensate pump in the
device. Secure the condensate pump
and push the condensate hose into the
pump.
Spare parts and customer service
If you have any queries regarding the
device, or wish to order spare parts, contact
your dealer or HEYLO.