6.1 PUMP FAILURE
PROBLEM
The pump does not
start up/The motor
does not turn.
The pump does not
prime/There may
be air in the strainer
basket.
Low flow rate/Low
filter pressure.
Low flow rate/High
filter pressure.
The pump makes a
lot of noise.
Leak in the body of
the pump and the
motor.
Installation and general maintenance manual
SOLUTION
Power cut. Check the circuit breakers.
Check the connection between the power cable and the motor' s terminals.
Check that the motor shaft is turning freely. Check that there is no debris
in the strainer basket.
If any debris still remains, remove the pump to access the turbine.
Check the position of the valves in the hydraulic circuit.
Air has clogged up in the circuit. Bleed the hydraulic circuit (bleed valve
on the filter).
The pool' s water level is too low, so the circuit is sucking in air. Fill the pool.
The strainer lid is defective. Check the state of repair of the gasket and that
the lid is watertight.
The strainer basket is full of debris. Clean it.
Air leak in the circuit. Check all of the tightening torques.
The turbine and pump diffuser are blocked or worn. Replace them.
The diffuser' s gasket is worn. Replace it.
Reverse rotation of the motor (only on three-phase pumps). Check the
connections of pump' s terminal blocks.
The filter is blocked up. Clean the filter (or cartridge, as may be the case).
Check the position of the valves in the hydraulic circuit.
Air leak or cavitation in the suction piping. Check the position of the valves
and adjust them whenever necessary.
Pump badly placed on the ground. Check that it is on a flat, hard, horizontal
surface. Use anti vibration pads whenever necessary.
There is a foreign body in the strainer basket.
There is a foreign body in the body of the pump. The pump must be
removed and taken for servicing.
The mechanical seal is damaged. Replace it.