5.5 Charging the battery (Fig. 10)
1. Take the battery pack out of the equipment.
Do this by pressing the side pushlock buttons.
2. Check that your mains voltage is the same as
that marked on the rating plate of the battery
charger. Insert the power plug of the charger
(d) into the socket outlet. The green LED will
then begin to fl ash.
3. Slot the battery pack (18) onto the battery
charger (d).
4. In the section entitled „Charger indicator" you
will fi nd a table with an explanation of the LED
indicator on the charger.
The battery pack can become a little warm during
the charging. This is normal.
If the battery pack fails to charge, check:
•
whether there is voltage at the socket outlet
•
whether there is good contact at the charging
contacts
If the battery pack still fails to charge, send
•
the charger
•
and the battery pack
to our customer service center.
To ensure that items are properly packaged
and delivered when you send them to us,
please contact our customer service or the
point of sale at which the equipment was
purchased.
When shipping or disposing of batteries and
cordless tools, always ensure that they are
packed individually in plastic bags to prevent
short circuits and fi res.
To ensure that the battery pack provides long ser-
vice, you should take care to recharge it promptly.
You must recharge the battery pack when you
notice that the performance of the device drops.
Never allow the battery pack to become fully di-
scharged. This will cause it to develop a defect.
Fitting the battery (Fig. 8)
Open the battery cover (15). To do so, fl ip the
cover up as shown in Fig. 8. Then slot the rechar-
geable battery (18) into the mount and push them
forward until you hear the battery engage.
Battery capacity indicator (Fig. 11)
Press the battery capacity indicator switch (a).
The battery capacity indicator (b) will indicate the
charge status of the battery by means of 3 LEDs.
Anl_TE_VC_18_10_Li_Solo_SPK13.indb 16
Anl_TE_VC_18_10_Li_Solo_SPK13.indb 16
GB
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED blinks:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.
6. Operation
6.1 ON/OFF switch (Fig. 1/2)
Switch position 0:
Off
Switch position I:
On
6.2 Dry vacuuming
Use the additional fi lter (16) for dry vacuuming
(see point 5.2).
Always ensure that the fi lters are securely seated.
6.3 Wet vacuuming
For wet-vacuuming, use the foam fi lter (14) (see
point 5.2).
Check that the fi lter is securely seated at all times.
When wet vacuuming, the fl oating safety switch
(Fig. 3/5) closes when the maximum tank level is
reached. At the same time, the suction noise of
the equipment will change and become louder.
You must then switch off the equipment and em-
pty the tank.
Danger!
The wet/dry vacuum is not suitable for the vacu-
uming of combustible liquids. For wet vacuuming,
use only the supplied foam fi lter.
6.4 Blowing
Connect the suction hose (10) to the blow con-
nector (9) on the wet/dry vacuum.
- 16 -
27.04.2022 09:18:15
27.04.2022 09:18:15