connection cable. The control signal to the
heating unit is fed over this cable.
To prevent interference, this cable must be
laid separately from lines carrying 230 V or
400 V. If external inductive influences can
be expected, for example from power ca-
bles, a shielded cable must be used.
Use electrical cable of the type NYM with the
following conductor cross section:
Cable length:
2
to 20 m
2
to 30 m
more than 30 m
Make sure that the cable is voltage-free.
Connect the remote control to the gas hea-
ting unit with the three conductor cable ac-
cording to the connection plan (
4.4

Putting into Operation

After connecting the electrical lines, insert
the top part of the remote control (a) on the
base (b) and put the gas heating unit into

operation.

5
Operation
Note: The TFQ 2 W is not an independent
regulator but rather a remote control with or
without room temperature sensing. It shifts
the heating curve of the TA... weather con-
trolled feed temperature regulator as requi-
red. It is therefore important that the settings
on the TA... regulator (e.g., heating curve)
are correct.
Important: So that the remote control can
have an effect on the TA... regulator, the
operational mode switch of the TA...E/A re-
gulator must be in position
The TFQ 2 W remote control has the follo-
wing control elements (
e
Cover
f
Operational mode switch
g
Adjustment knob for normal mode
h
Adjustment knob reduced mode
i
Plexiglas disk with printed clock hand
10
Cross section:
0.75 to 1.5 mm
1.00 to 1.5 mm
2
2
1.50 mm
7
to
or
1
and
3
):
j
7-Day ring
k
Storage for reserve riders
l
Riders in red or blue
m
Time marker for 7-day ring
n
Brief operating instructions:
In the compartment on the right side of
the base, a small instruction manual
(JU 1011) can be found. It contains all
essentials for operation in brief form.
5.1
Mode Switch (f)
2
The following operating modes are possible:
2
Freeze protection mode: For outside
temperatures above + 4 °C, the heating
unit and the circulation pump are swit-
ched off (exception: For the TA 210 A,
the pump runs continuously). In case a
mixing valve is installed, this is driven
11
).
to the position "closed". For outside
temperatures below + 3 °C, the heating
unit is regulated to the minimum tempe-
rature set on the TA regulator. The cir-
culation pump runs according to the
pump switching logic. In case a mixing
valve is present, this is regulated to a
feed temperature of + 10 °C.
Normal mode: Continuous regulation of
the temperature to the value set on the
knob (g). See Section 5.3.1. for the
temperature range. The time has no
function.
Economy mode: Continuous reduction
of the feed temperature of approx. 25 K
for operation of the TFQ 2 W without
room temperature sensing or the room
temperature by approx. 3 K for operati-
on with room temperature sensing.
The knob (h) has no function in this
.
mode of operation.The reduction value
set on the TA...E/A regulator has no ef-
fect. The circulation pump runs accor-
ding to the pump switching logic.
Normal/Freeze protection mode: Auto-
matic switching between the normal
and freeze protection modes according
to the timer programming.
Note: In the freeze protection mode,
the operational characteristics as de-
scribed under
TFQ 2 W
apply.