CONTROL CABLE
Cat 5e or Cat 6 cable must be used to connect the microphone with the PA switchboard or several
microphones in cascade. This cable is composed of 8 conductors which must be connected according to
the previous diagram and both end in RJ-45 connectors (8P8C).
For example, the following colour code can be used:
Connector A:
1- Blue
2- Blue/White
3- Brown
4- Brown/White
5- Orange
6- Orange/White
7- Green
8- Green/White
The numbering of the different cables is displayed on the front of the RJ-45 connector.