Terminals
1
Press MENU until the SET UP 3 display appears
on the screen.
2
Press SHIFT v to move the flashing to TAPE END
OUT and set to –3M or END by pressing DATA
'/'.
<SET UP 3>
ALARM MODE
ALARM SPEED
ALARM DURATION
EXT TIME ADJ.
TAPE IN MODE
TAPE END MODE
TAPE END OUT
CLOG DETECT.
SERIES REC
3
Press PAUSE/SEARCH to return to the normal
display.

SW OUT Terminal

The VCR outputs a pulse signal from the SW (switch)
OUT terminal to the camera switcher to control the
switching from camera to camera.
COM terminal
SW OUT terminal
Specify the interval between each pulse signal on the
SET UP 4 display. Also, set TIMING to FIELD or
FRAME depending on the specifications of the camera
switcher.
Available settings are:
• FIELD: 1, 2, 3, 4, 5, 10, 30, or 60 fields
• FRAME: 1, 2, 3, 4, 5, 10, 30, or 60 frames
1
Press MENU until the SET UP 4 display appears
on the screen.
<SET UP 4>
∗SW OUT
FIELD
01
TIMING
FIELD
6H
Y
<USED TIME>
01 of FIELD is flashing.
36
Y1
6H
20S
01:00
STOP
REW
-3M
Y
N
2
Set the interval by pressing DATA '/' and press
SHIFT b.
<SET UP 4>
∗SW OUT
FIELD
04
TIMING
FIELD
6H
Y
<USED TIME>
3
Set TIMING to FIELD or FRAME by pressing
DATA '/'.
<SET UP 4>
∗SW OUT
FRAME
04
TIMING
FRAME
6H
Y
<USED TIME>
4
When the TAPE switch is set to T-120:
Set 6H (6-hour mode) to Y (yes) or N (no) by
pressing DATA '/'.
Y (yes): a signal is output in the 6-hour mode
N (no): a signal is not output in the 6-hour mode
When the TAPE switch is set to T-160:
Set 8H (8-hour mode) to Y (yes) or N (no) by
pressing DATA '/'.
Y (yes): a signal is output in the 8-hour mode
N (no): a signal is not output in the 8-hour mode
5
When you have completed the settings, press
PAUSE/SEARCH to return to the normal display.