NOTE: In order to increase the dosing accuracy, please consider the desired, actual dosing liquid volume during
calibration. The calibration fluid volumes can be set to 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 (ml), the calibration
duration is stored in memory. The closer the calibration volume is to the actual dosing liquid volume, the more
accurate the actual dosing will be.
Fig. 9: For example, if the user wants the pump to automatically dose about 40 ~ 60 ml of the liquid, then 50
ml should be entered as the calibration volume. The calibration time is automatically saved in memory.

4.3. Timer mode

Fig. 10: Tap and hold the channel icon to go to the channel settings page. Touch the > icon next to "Automatic
Program" to open the timer settings page.
Fig. 11: You can set the interval days, the required dosage and the associated time. The interval days indicate
how many days should elapse between two doses (interval 0 = daily dose, interval 1 = every two days,
etc.). When the setup is complete, click "SAVE".