ENGLISH
(d) Rinsing
Circulate water to wash away the remaining chemical in the water circuit (4 times).
Display
(e) Circuit washing
Wash the chemical feeding line with water.
Display
(f) Draining
Thoroughly drain the water used for cleaning.
Display
4) When the display returns to "oFF", the trial run is completed.
- Check for water leakage in the unit.
- Check the unit for error stop.
5) Press the ON/OFF button to start the icemaking operation.
2. CHEMICAL REPLACEMENT
When the citric acid pack becomes empty, the display shows "n93".
The citric acid pack needs to be refilled or replaced.
[a] Replacement
1) Take the empty citric acid pack out from the unit as follows.
Step 1
Remove the louver.
Remove the thumbscrews at the louver bottom by hand. Hold
the louver bottom with both hands, pull it a little towards you,
and lift it up.
Step 2
Remove the pack.
Press the button to unlock the coupling, and then disconnect
the pack assy from the coupling.
10
Cap Nut