OPERATING AND MAINTENANCE MANUAL
SBM SERIES SELF-PRIMING PUMP
8. PROBLEM SOLVING
ENG
Caution. Disconnect the pump from the power source BEFORE performing any work,
repair or maintenance on the equipment.
PROBLEMS
The pump does
not run
The pump does
not pump properly
The pump runs
but no water
The flow reduces
obviously
The motor is
over heat
The pump stops
soon after
starting
POSSIBLE REASONS
1. The motor is rocked.
2. The voltage does not match.
3. Fuse or thermal protector makes
thepump stop running.
1. The head is too high.
2. The water level is too low.
3. The bottom valve is not in the water.
4. No water.
5. The inlet pipe is leakage.
1. The foot-valve is blocked.
2. The impeller is corrosive.
3. The bottom valve is not in the water.
4. No priming water.
5. The inlet pipe is leakage.
1. The foot-valve is blocked.
2. The head is too high.
3. The water level is too low.
4. The impeller is serious damage.
1. The voltage does not match.
2. Bad ventilation in the operation room.
1. The motor is locked.
2. The voltage is too low.
3. Bad ventilation in the operation room.
www.proindecsa.com / proindecsa@proindecsa.com
SOLUTION
1. Send to the service center.
2. Check the voltage on the name plate.
3. Check the fuse or thermal protector.
1.Check the height of installation if it meets the
head.
2. Check the suction height.
3. Have the valve in the water.
4. Fill the pump with water.
5. Check whether the pipe is leakage.
1. Check the suction height and re-install the
pump.
2. Replace the impeller.
3. Fill the inlet section with water.
4. Fill the pump with water.
5. Check whether the pipe is leakage.
1. Clean or replace the foot-valve.
2. Check the height of installation whether is the
same as normal doing.
3. Check the suction height and re-install the
pump.
4. Replace the impeller.
1. Contact the electric power company to supply
stable voltage.
2. Have good ventilation.
1. Disconnect the pipe and send to the service
center.
2. Contact the electric power company to supply
stable voltage.
3. Have good ventilation.