Anti-Tip Bracket - Sub-Zero Classic Serie Guia De Instalacion

Ocultar thumbs Ver también para Classic Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Site Preparation

Anti-Tip Bracket

WARNING
To prevent the unit from tipping forward, the anti-tip
brackets must be installed.
The two anti-tip brackets must be installed exactly 24"
from the front of the opening to the back of the
(610)
brackets and a minimum of 4"
opening. This depth will increase to 26 3/16"
inset installation based on 3/4"
properly position the anti-tip brackets will prevent proper
engagement.
Use all anti-tip bracket hardware as instructed for wood or
concrete floors.
IMPORTANT NOTE: For wood or concrete floor applica-
tions, if the #12 screws do not hit a wall stud or wall plate,
use the #8 screws and #12 washers with the wall anchors.
IMPORTANT NOTE: In some installations the subflooring
or finished floor may necessitate angling the screws used
to fasten the anti-tip brackets to the back wall.
ANTI-TIP HARDWARE
2
Anti-tip brackets
12
#12 x 2 1/2" pan head screws
4
3/8"–16 x 3 3/4" wedge anchors
12
#12 flat washers
4
#8–18 x 1 1/4" truss head screws
4
Nylon Zip-it® wall anchors
10 | Sub-Zero Customer Care 800.222.7820
from the sides of the
(102)
for a flush
(665)
thick panels. Failure to
(19)
WOOD FLOOR APPLICATION
After properly locating the anti-tip brackets in the open-
ing, drill pilot holes 3/16"
diameter maximum in the wall
(5)
studs or wall plate. Use the #12 screws and washers to
secure the brackets. Verify the screws penetrate through
the flooring material and into the wall studs or wall plate a
minimum of 3/4"
. Refer to the illustration below.
(19)
CONCRETE FLOOR APPLICATION
After properly locating the anti-tip brackets in the opening,
drill pilot holes 3/16"
diameter maximum in the wall studs
(5)
or wall plate. Drill 3/8"
diameter holes into the concrete
(10)
a minimum of 1 1/2"
deep. Use the #12 screws and
(38)
washers to secure the brackets to the wall, and use the 3/8"
wedge anchors to secure the brackets to the floor. Verify
the screws penetrate the wall studs or wall plate a mini-
mum of 3/4"
. Refer to the illustration below.
(19)
24"
(610)
4"
(102)
MIN
FINISHED
FLOORING
WALL PLATE
SUBFLOORING
WOOD FLOOR
Wood floor
24"
(610)
4"
(102)
MIN
FINISHED
FINISHED
FLOORING
FLOORING
WALL PLATE
WALL PLATE
SUBFLOORING
SUBFLOORING
1
1
1
/
/
"
"
1
2
2
(38)
(38)
CONCRETE
CONCRETE
min
MIN
FLOOR
FLOOR
Concrete floor