Descargar Imprimir esta página

Purging Air From The Pump - Simpson Megashot MS61220 Manual De Uso Y Cuidado

Publicidad

Idiomas disponibles

Idiomas disponibles

PURGING AIR FROM THE PUMP

Running a pressure washer pump without water will severely damage the pump seals
and other internal components. To avoid this hazard, make sure your water supply is
uninterrupted and at least 5 GPM at 20 PSI, and always purge the air your pressure
washer pump before starting the engine.
The high pressures created by a pressure washer can cause fluid injection injuries,
severe lacerations, amputations, and / or death. To avoid these hazards, always aim
the spray gun and lance in a safe direction when using the pressure washer and never
attempt to touch a leak in a high-pressure hose or fitting.
A pressure washer pump is designed to operate with water flowing through it. Water
lubricates and cools the internal components of the pump. Running a pressure washer pump
without water will severely damage the pump seals and other internal components. Damage
caused by running a pressure washer pump without water is not covered under warranty.
Be sure to follow the instructions below to correctly purge the air from your pressure washer
pump before starting the engine.
1.
Connect all the hoses by following the steps outlined in the CONNECTING HOSES
section of this manual then turn on the cold water source.
2.
Aim the spray gun in a safe direction
then squeeze and hold the trigger for
at least 30 seconds or until the water
runs steady and all the air is purged
from the pump and hoses.
3.
Check hoses and connections for leaks. If leaks are found, turn off the machine, aim the
spray gun in a safe direction and squeeze the trigger to relive any built up pressure in the
system. Never attempt to touch a leak in a high-pressure hose or fitting. Never attempt to
repair a high-pressure hose.
Page 11
INJECTION INJURY
MS61220/MS61221- ENGLISH
PUMP PURGING
REV 2 - 01/03/2022