Descargar Imprimir esta página

General Safety Notes; Notes On Ul Approval; Intended Use; Operating Elements And Status Indicators - SICK WTB4S-3 Manual De Instrucciones

Ocultar thumbs Ver también para WTB4S-3:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 25
1

GENERAL SAFETY NOTES

1
General safety notes
2

Notes on UL approval

en
3

Intended use

4

Operating elements and status indicators

16
O P E R A T I N G I N S T R U C T I O N S | WTB4S-3
Read the operating instructions before commissioning.
Connection, mounting, and configuration may only be performed by trained
specialists.
NO
2006/42/EC
Not a safety component in accordance with the EU Machinery Directive.
SAFETY
Do not install the sensor at locations that are exposed to direct UV radiation
(sunlight) or other weather influences, unless this is expressly permitted in the
operating instructions.
When commissioning, protect the device from moisture and contamination.
These operating instructions contain information required during the life cycle of
the sensor.
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a)
max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b)
100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
The WTB4S-3 is an opto-electronic photoelectric background suppression proximity
sensor (referred to as "sensor" in the following) for the optical, non-contact detection of
objects, animals, and persons. If the product is used for any other purpose or modified
in any way, any warranty claim against SICK AG shall become void.
Table 6: Operating elements and status indicators
Yellow LED: status of received light beam
1
Green LED: supply voltage active
2
Potentiometer
3
Potentiometer
1
2
3
8027693.1E52/2022-03-21 | SICK
Subject to change without notice

Publicidad

Solución de problemas

loading