Before you start
01
To install batteries
1. This instrument requires 1x1.5V button cell (not included).
2. Remove the battery compartment cover.
3. Insert the batteries paying attention to the polarity (+/-)
marked on the compartment and batteries.
4. Close the battery compartment cover.
CAUTION:
• ALWAYS turn off the instrument before replacing the batteries.
• ALWAYS remove the batteries if the instrument is not to be used for extended periods.
• ALWAYS use high quality batteries of the same brand, type and age.
• If the instrument does not work properly, or the low battery icon is displayed,
replace the batteries immediately.
• DO NOT expose the batteries or instrument to extreme temperatures or direct
heat source, as this can cause the batteries to leak.
• If the batteries should leak, remove them using a cloth and dispose of them
according to local regulations. Clean any leaked battery acid avoiding any contact
with skin, eyes & mouth.
• If any contact does occur, rinse affected areas immediately with fresh water and
seek medical advice.
Functions and settings
01
Operation
1. Ensure all measurement faces are clean before use.
2. Loosen locking screw (3).
3. Switch ON pressing power button (6).
4. Select metric or imperial units by pressing button (2).
5. Close jaws applying normal pressure and pressing zero button (7).
TECH10593 Micrometer A5 V6R.indd 4
Utilisation
Uso
Utilização
Benutzung
mm/inch
OFF
ON
ZERO
4