Descargar Imprimir esta página

Cleaning And Maintenance; Replacing The Fuse; Technical Specifications - HQ-Power HQSM10005 Manual Del Usuario

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

8.
Troubleshooting
There is no power.
Check the mains power supply.
Check the fuse.
There is no fog output.
Check the fluid level.
Check the remote control.
The remote control does not work.
Make sure the remote control is well connected.
The fluid tank is filled but the sensor indicates it is not.
Try resetting the smoke machine by switching it off and on again.
Contact your dealer if the problem persists.
The smoke machine is not heating up.
Contact your dealer.
9.

Cleaning and Maintenance

Before starting any cleaning or maintenance activities:
1.
Unplug the device's power cord from the outlet.
2.
Let the device cool down.
Cleaning
Make sure to empty the tank before cleaning.
Use normal glass cleaner and a soft cloth to wipe off the outside casing.
Clean the external optics with glass cleaner and a soft cloth every 20 days.
Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the unit operates (i.e. smoke, fog residue,
dust, dew).
Do not immerse the device in any liquid.
Maintenance
All screws should be tightened and free of corrosion.
The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension,
trussing) should not be deformed, modified or tampered with; e.g. do not drill extra holes in
mounting supports, do not change the location of the connections...
Mechanically moving parts must not show any signs of wear and tear.
The electric power supply cables must not show any damage. Have a qualified technician maintain
the device.
There are no user-serviceable parts, apart from the fuse and the lamp.
Refer to an authorized dealer for service and/or spare parts.
9.2

Replacing the fuse

1.
Unplug the device's power cord from the outlet.
2.
Let the device cool down.
3.
Remove the rear cover with a flat-head screwdriver.
4.
Open the fuse holder.
5.
Replace with an appropriate fuse.
6.
Insert the fuse holder back in its place, replace the rear cover and reconnect power.
10.

Technical Specifications

power supply ......................................................................... 220-240 V~, 50/60 Hz
power consumption ..................................................................................... 1500 W
fuse ............................................................................................................... F8A
heating time ................................................................................................. 6 min.
output ......................................................................... ca. 1132 m³, 40000 ft³/min.
tank capacity ................................................................................................. 2.5 L
V. 01 – 06/01/2016
HQSM10005
9
©Velleman nv

Publicidad