4. Connector Plate

Dual BNC coaxial input and outputs, 75 Ohm
Cables up to 100 meters in length may be used.
SC-plug duplex fiber-optic connector (IEC874-19)
Use SC duplex connectors and multimode fiber-optic
cable with 50-micron core / 125-micron cladding
diameters, or a 62.5-micron core / 125-micron
cladding diameters.
Cables up to 2 km in length may be used.

5. Specifications

Connectors
Duplex fibre-optic, SC-plug, IEC874-19
MADI (AES10) BNC INPUT
MADI (AES10) BNC OUTPUT
Input/Output Characteristics
Channels of input/output to X32, max.
Channels of input/output to MADI (AES10-2003)
Sample rates
Sample word length
Clock synchronization selectable
Round-trip latency
Cable Length
Fibre-optic, multimode cable, max
(125 µm cladding, 50/62.5 µm core)
BNC, coaxial 75-Ohm, max
All manuals and user guides at all-guides.com
1
1
1
32 / 32
64 / 64
44.1 kHz / 48 kHz
24 Bit
internal/Local or
BNC clock input or
fibre optic input
<150 µs
2 km
100 m
2x small handles for removing the expansion card
from the slot
2x M3x6 screws for fastening the card in the slot
3 countersunk M3 screws for fixing the pcb.
Don't loosen these!