L5BY2_US(VCC-P6784)(GB_FR_ES).book 28 ページ 2007年12月7日 金曜日 午後3時39分
Configuring the Communication Settings
The camera can be operated remotely by connecting a digital video recorder or controller as a communication device. You
need to configure the conditions for the communication to function.
1
Select [OPTION] and press the SET button.
RThe OPTION screen appears.
Setting Protocol for Camera Controller
<CONTROL>
2
Select [CONTROL] and specify the protocol for
controlling the camera.
OPTION
TITLE
OFF
PRIVACY MASK
SET
PASSWORD
SET
ALARM
SET
LANGUAGE
SET
·
CONTROL
COAX
ADDRESS
1
ALARM LINE OUT
OFF
PRESET
OFF
MENU
BACK
COAX : Coaxial superposition (SANYO: using coaxial cable)
• SSP, Hi-speed SSP and PELCO-C are supported.
Switching among the three is automatic.
485S : RS-485 (SANYO)
• Both SSP and Hi-speed SSP are supported. Switching
between the two is automatic.
485P : RS-485 (PELCO-D)
All manuals and user guides at all-guides.com
y
y
y
y
y
3
For advanced settings (485S or 485P), press the
SET button.
RThe CONTROL SETTING screen appears.
7
• Advance to step
if you have selected "COAX".
4
Select [BAUD RATE] and specify the
communication speed.
CONTROL SETTING
·
BAUD RATE
19200
TERMINATE
OFF
PRESET
OFF
MENU
BACK
• Select from: 19200, 9600, 4800, 2400
☞
Continued to the next page.
28
GB