• Note the high centre of gravity of the machine (top
heavy).
•
m Attention!If the machine is tilted, it can tip over.
12. Maintenance
Only carry out modifications, setting, measuring
and cleaning work when the engine is switched
off. Pull out the mains plug and wait for the rotat-
ing tool to stop.
All protective and safety equipment must be reas-
sembled immediately after repair, maintenance is
completed.
The built-in ball bearings are maintenance-free.
General maintenance tasks
Wipe swarf and dust off the machine from time to time
with a cloth. Oil the rotating parts once monthly to ex-
tend the life of the tool. Do not oil the motor.
Do not use corrosive agents for cleaning the plastic.
Our recommendation to you:
Slightly grease the swivel segments of the table
1.
and the belt tensioning device.
2.
Clean the saw band regularly. Wood leaves resin
residues. For cleaning, we recommend the res-
in removal concentrate Pharmol HEK, item no.
61009700.
Check the guide rollers and the counterpres-
3.
sure bearings regularly. If necessary, readjust or
dismantle and oil or replace.
4.
Replace used table inlays.
5.
Always keep the tabletop free of resin.
6.
Regularly lightly oil the bearing points of the
handwheel.
7.
In the course of time, the rubber wrapping on the
blade wheels cracks and gets worn due to the met-
al saw band. This prevents the saw blade from op-
erating precisely. Workplace safety and machine
operation are adversely affected by this. Replace
the band wheels!
Cleaning
Keep protective devices, air vents and the motor hous-
ing as free of dust and dirt as possible. Rub the device
clean with a clean cloth or blow it off with compressed
air at low pressure.
We recommend that you clean the device directly after
every use.
46 | GB
Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can pen-
etrate the device interior. Water penetrating an electric
device increases the risk of an electric shock.
Service information
With this product, it is necessary to note that the fol-
lowing parts are subject to natural or usage-related
wear, or that the following parts are required as con-
sumables.
Wearing parts*:Saw band, table inserts; V-belt
* may not be included in the scope of supply!
Spare parts and accessories can be obtained from our
Service Centre. To do this, scan the QR code on the
front page.
13. Storage
Store the device and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electric tool in its original packaging.
Cover the electric tool to protect it from dust or mois-
ture.
Store the operating manual with the electric tool.
14. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
www.scheppach.com